Literature DB >> 19102576

The effect of screw pullout rate on screw purchase in synthetic cancellous bone.

Rad Zdero1, Emil H Schemitsch.   

Abstract

Clinically, orthopaedic fracture fixation constructs are mounted using screws inserted into cancellous bone, while biomechanical studies are increasingly using commercially available synthetic bones. The goal of this study was to examine the effect of screw pullout rate on cancellous bone screw purchase strength in synthetic cancellous bone. Sixty synthetic cancellous bone cubes (40x40x40 mm(3)) each had one orthopaedic cancellous bone screw (major diameter=6.5 mm) inserted to a depth of 30 mm. Screws were extracted to obtain outcome measures of failure force, failure shear stress, failure energy, failure displacement, resistance force, and removal energy. The ten test groups (n=6 cubes per group) had screws extracted at pullout rates of 1 mmmin, 2.5 mmmin, 5 mmmin, 7.5 mmmin, 10 mmmin, 20 mmmin, 30 mmmin, 40 mmmin, 50 mmmin, and 60 mmmin. The aggregate average results for failure force, failure stress, failure energy, failure displacement, resistance force, and postfailure removal energy for combined pullout rates were, respectively, 984.8+/-63.9 N, 3.5+/-0.2 MPa, 298.3+/-41.7 J, 0.53+/-0.08 mm, 453.8+/-19.6 N, and 5420.1+/-489.7 J. Most statistical differences (40 of 47) involved either the 5 mmmin or the 60 mmmin rates being compared to other rates. Failure force, failure stress, and resistance force increased and were highly linearly correlated with pullout rate (R(2)=0.78, 0.76, and 0.74, respectively). Failure energy, failure displacement, and removal energy were relatively unchanged over the pullout range tested, yielding low correlation coefficients (R(2)<0.05). Failure force, failure stress, and resistance force were affected by bone screw pullout rate in synthetic cancellous bone, while failure energy, failure displacement, and removal energy remained unchanged. This is the first study to perform an extensive investigation of cancellous bone screw pullout rate in synthetic cancellous bone.

Entities:  

Mesh:

Year:  2009        PMID: 19102576     DOI: 10.1115/1.3005344

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.

Authors:  Matthew C Avery; Sally Jo; Andrew Chang; William M Ricci; Christopher McAndrew; Anna N Miller; Simon Tang
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

2.  Balancing rigidity and safety of pedicle screw fixation via a novel expansion mechanism in a severely osteoporotic model.

Authors:  Thomas M Shea; James J Doulgeris; Sabrina A Gonzalez-Blohm; William E Lee; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2015-02-01       Impact factor: 3.411

3.  Fixation stability comparison of bone screws based on thread design: buttress thread, triangle thread, and square thread.

Authors:  Xiaoreng Feng; Zhaopei Luo; Yupeng Li; Yiyi Yao; Weichen Qi; Bin Chen; Hongfeng Liang
Journal:  BMC Musculoskelet Disord       Date:  2022-08-30       Impact factor: 2.562

  3 in total