Intracardiac calipers for artificial chordae replacement in mitral valve repair.

Atsuo Doi1, Hiroshi Iida, Toru Sunazawa.   

Abstract

Length adjustment of artificial chordae is crucial in the outcome of anterior mitral valve repair. Herein, a simple and reproducible method of artificial chordal replacement using polytetrafluoroethylene suture is described. With this technique, the length of the neo-chordae is easily decided and the knot can be tied surely without change in the length using only one instrument.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19101333     DOI: 10.1016/j.athoracsur.2008.05.033

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

Review 1.  Different ways to repair the mitral valve with artificial chordae: a systematic review.

Authors:  Federico Bizzarri; Antonella Tudisco; Massimo Ricci; David Rose; Giacomo Frati
Journal:  J Cardiothorac Surg       Date:  2010-04-08       Impact factor: 1.637

2.  Beating-heart mitral valve chordal replacement.

Authors:  Genevieve Laing; Pierre E Dupont
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

Review 3.  Artificial chordae for degenerative mitral valve disease: critical analysis of current techniques.

Authors:  Michael Ibrahim; Christopher Rao; Thanos Athanasiou
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-09-07

4.  Mitral valve repair in children with rheumatic heart disease.

Authors:  Srirup Chatterjee; Nikhil Bansal; Rajarshi Ghosh; Lakshmi Kumari Sankhyan; Sujoy Chatterjee; Santosh Pandey; Satyajit Bose
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-03-25

5.  Neochordameter: a new technology in mitral valve repair.

Authors:  Alireza Alizadeh-Ghavidel; Niloofar Samiei; Hoda Javadikasgari; Kamiar Bashirpour
Journal:  Res Cardiovasc Med       Date:  2013-10-28

6.  Quadrangular resection versus chordal replacement for degenerative posterior mitral leaflet prolapse.

Authors:  Jiexu Ma; Jian Liu; Peijian Wei; Ximeng Yao; Yuyuan Zhang; Liangzheng Fang; Zhao Chen; Yanjun Liu; Tong Tan; Hongxiang Wu; Huanlei Huang; Bin Xie; Jimei Chen; Jian Zhuang; Huiming Guo
Journal:  Ann Transl Med       Date:  2021-01

7.  Real-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair.

Authors:  Huan-lei Huang; Xu-jing Xie; Hong-wen Fei; Xue-jun Xiao; Jing Liu; Jian Zhuang; Cong Lu
Journal:  J Cardiothorac Surg       Date:  2013-05-30       Impact factor: 1.637