Literature DB >> 19100591

A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers.

I Bazán1, M Vazquez, A Ramos, A Vera, L Leija.   

Abstract

Optimization of efficiency in hyperthermia requires a precise and non-invasive estimation of internal distribution of temperature. Although there are several research trends for ultrasonic temperature estimation, efficient equipments for its use in the clinical practice are not still available. The main objective of this work was to research about the limitations and potential improvements of previously reported signal processing options in order to identify research efforts to facilitate their future clinical use as a thermal estimator. In this document, we have a critical analysis of potential performance of previous ultrasonic research trends for temperature estimation inside materials, using different processing techniques proposed in frequency, time and phase domains. It was carried out in phantom with scatterers, assessing at their specific applicability, linearity and limitations in hyperthermia range. Three complementary evaluation indexes: technique robustness, Mat-lab processing time and temperature resolution, with specific application protocols, were defined and employed for a comparative quantification of the behavior of the techniques. The average increment per degrees C and mm was identified for each technique (3 KHz/ degrees C in the frequency analysis, 0.02 rad/ degrees C in the phase domain, while increments in the time domain of only 1.6 ns/ degrees C were found). Their linearity with temperature rising was measured using linear and quadratic regressions and they were correlated with the obtained data. New improvements in time and frequency signal processing in order to reveal the potential thermal and spatial resolutions of these techniques are proposed and their subsequent improved estimation results are shown for simulated and measured A-scans registers. As an example of these processing novelties, an excellent potential resolution of 0.12 degrees C into hyperthermia range, with near-to-linear frequency dependence, could be achieved. Specifically defined "numerical" and physical multi-scatter phantoms are described, which mimic ultrasound velocity in tissues of about 1560 m/s @ 35 degrees C and have a quasi-uniform internal scattering structure designed to assure standard signal patterns adequate for processing comparisons in the same time and sound velocity conditions for all the techniques analyzed, and to obtain easily repeatable multi-pulse echo-patterns. A perfect lineal dependence (100% of correlation coefficient) between the unitary average increment measured by each technique and temperature rising was observed while working with simulated A-scan registers, where all the parameters are under an accurate control. Nevertheless a very small quadratic tendency appeared in the results obtained from experimental echo registers, which are more similar to a real tissues case. It would be an interesting future work to analyze the behavior of these techniques in real tissues in order to confirm or reject this light quadratic tendency. Finally, new methods were detailed and applied in order to precisely quantify the advantages of each estimation technique; their respective intrinsic limitations were also underlined.

Entities:  

Mesh:

Year:  2008        PMID: 19100591     DOI: 10.1016/j.ultras.2008.10.012

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  7 in total

Review 1.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

2.  Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

Authors:  Noraida Abd Manaf; Maizatul Nadwa Che Aziz; Dzulfadhli Saffuan Ridzuan; Maheza Irna Mohamad Salim; Asnida Abd Wahab; Khin Wee Lai; Yan Chai Hum
Journal:  Med Biol Eng Comput       Date:  2016-04-02       Impact factor: 2.602

3.  Possible patient early diagnosis by ultrasonic noninvasive estimation of thermal gradients into tissues based on spectral changes modeling.

Authors:  I Bazan; A Ramos; H Calas; A Ramirez; R Pintle; T E Gomez; C Negreira; F J Gallegos; A J Rosales
Journal:  Comput Math Methods Med       Date:  2012-05-13       Impact factor: 2.238

4.  A new high-resolution spectral approach to noninvasively evaluate wall deformations in arteries.

Authors:  Ivonne Bazan; Carlos Negreira; Antonio Ramos; Javier Brum; Alfredo Ramirez
Journal:  Comput Math Methods Med       Date:  2014-02-13       Impact factor: 2.238

5.  Calibration Method of an Ultrasonic System for Temperature Measurement.

Authors:  Chao Zhou; Yueke Wang; Chunjie Qiao; Weihua Dai
Journal:  PLoS One       Date:  2016-10-27       Impact factor: 3.240

6.  Estimation of PSD shifts for high-resolution metrology of thickness micro-changes with possible applications in vessel walls and biological membrane characterization.

Authors:  Antonio Ramos; Ivonne Bazán; Carlos Negreira; Javier Brum; Tomás Gómez; Héctor Calás; Abelardo Ruiz; José Manuel de la Rosa
Journal:  Sensors (Basel)       Date:  2012-11-09       Impact factor: 3.576

7.  Uncertainty estimation for temperature measurement with diagnostic ultrasound.

Authors:  Tina A Fuhrmann; Olga Georg; Julian Haller; Klaus-V Jenderka; Volker Wilkens
Journal:  J Ther Ultrasound       Date:  2016-12-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.