Literature DB >> 19100554

Effect of phenyl sepharose ligand density on protein monomer/aggregate purification and separation using hydrophobic interaction chromatography.

Justin T McCue1, Philip Engel, Jörg Thömmes.   

Abstract

In the large-scale manufacturing and purification of protein therapeutics, multiple chromatography adsorbent lots are often required due to limited absorbent batch sizes or during replacement at the end of the useful column lifetime. Variability in the adsorbent performance from lot to lot should be minimal in order to ensure that consistent product purity and product quality attributes are achieved when a different lot or lot mixture is implemented in the process. Vendors of chromatographic adsorbents will often provide release specifications, which may possess a narrow range of acceptable values. Despite relatively narrow release specifications, the performance of the adsorbent in a given purification process could still vary from lot to lot. In this case, an alternative use test (one that properly captures the lot to lot variability) may be required to determine an acceptable range of variability for a specific process. In this work, we describe the separation of therapeutic protein monomer and aggregate species using hydrophobic interaction chromatography, which is potentially sensitive to adsorbent lot variability. An alternative use test is formulated, which can be used to rapidly screen different adsorbent lots prior to implementation in a large-scale manufacturing process. In addition, the underlying mechanism responsible for the adsorbent lot variability, which was based upon differences in protein adsorption characteristics, was also investigated using both experimental and modeling approaches.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19100554     DOI: 10.1016/j.chroma.2008.12.002

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  A new thermodynamic model describes the effects of ligand density and type, salt concentration and protein species in hydrophobic interaction chromatography.

Authors:  R W Deitcher; J E Rome; P A Gildea; J P O'Connell; E J Fernandez
Journal:  J Chromatogr A       Date:  2009-08-03       Impact factor: 4.759

Review 2.  Different Stationary Phase Selectivities and Morphologies for Intact Protein Separations.

Authors:  A Astefanei; I Dapic; M Camenzuli
Journal:  Chromatographia       Date:  2016-09-23       Impact factor: 2.044

3.  Size-Exclusion Chromatography for the Analysis of Protein Biotherapeutics and their Aggregates.

Authors:  Paula Hong; Stephan Koza; Edouard S P Bouvier
Journal:  J Liq Chromatogr Relat Technol       Date:  2012-11-30       Impact factor: 1.467

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.