Literature DB >> 19099236

Simultaneous determination of methamphetamine, 3,4-methylenedioxy-N-methylamphetamine, 3,4-methylenedioxy-N-ethylamphetamine, N,N-dimethylamphetamine, and their metabolites in urine by liquid chromatography-electrospray ionization-tandem mass spectrometry.

Jin Young Kim1, Jae Chul Cheong, Beom Jun Ko, Sang Kyu Lee, Hye Hyun Yoo, Changbae Jin, Moon Kyo In.   

Abstract

A liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed and validated for the simultaneous detection and quantification of seven amphetamine derivatives (amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxy-N-amphetamine (MDA), 3,4-methylenedioxy-N-methamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), N,N-dimethylamphetamine (DMA), and N,N-dimethylamphetamine-N-oxide (DMANO)) in human urine. Seven deuterium-labeled compounds were prepared for use as internal standards to quantify the analytes. One milliliter of urine was combined with 1 mL of 0.2 M sodium carbonate buffer solution (pH 9.0) before solid phase extraction (SPE). An Oasis HLB SPE column followed by chromatographic separation on a Capcell Pak C18 MG-II column (150 x 2.0 mm I.D., 5 microm) and electrospray mass spectrometry with multiple reaction monitoring were used for selective and sensitive detection. The use of ammonium formate (5 mM, pH adjusted to 4.0 with formic acid, Solvent A) and acetonitrile (Solvent B) as the mobile phase at a flow rate of 230 microL/min was found to be the most effective for the separation. The linear ranges were 5.0-1000 ng/mL for AP, MDA, MDMA, MDEA, DMA, and DMANO and 10.0-1000 ng/mL for MA, with good correlation coefficients (r2 > 0.996). The intra-day, inter-day, and interperson precisions were within 14.6%, 12.1% and 15.5%, respectively. The intra-day, inter-day, and interperson accuracies were between -11.6 and 9.0%, -7.9 and 2.3%, and -13.2 and 4.3%, respectively. The limits of detection (LODs) for each analytical compound were lower than 1.95 ng/mL. The recovery ranged from 72.3 to 103.3%. The applicability of the developed method was examined by analyzing several urine samples from confirmed drug abusers.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19099236     DOI: 10.1007/s12272-001-2163-5

Source DB:  PubMed          Journal:  Arch Pharm Res        ISSN: 0253-6269            Impact factor:   4.946


  2 in total

1.  Enhanced methamphetamine metabolism in rhesus macaque as compared with human: an analysis using a novel method of liquid chromatography with tandem mass spectrometry, kinetic study, and substrate docking.

Authors:  Ravinder Earla; Santosh Kumar; Lei Wang; Steven Bosinger; Junhao Li; Ankit Shah; Mohitkumar Gangwani; Anantha Nookala; Xun Liu; Lu Cao; Austin Jackson; Peter S Silverstein; Howard S Fox; Weihua Li; Anil Kumar
Journal:  Drug Metab Dispos       Date:  2014-10-09       Impact factor: 3.922

2.  Application of LC-MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids.

Authors:  Jamshed Haneef; Mohammad Shaharyar; Asif Husain; Mohd Rashid; Ravinesh Mishra; Shama Parveen; Niyaz Ahmed; Manoj Pal; Deepak Kumar
Journal:  J Pharm Anal       Date:  2013-04-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.