Analysis of dose perturbation factors of a NACP-02 ionization chamber in clinical electron beams.

E Chin1, H Palmans, D Shipley, M Bailey, F Verhaegen.   

Abstract

For well-guarded plane-parallel ionization chambers, international dosimetry protocols recommend a value of unity for electron perturbation factors in water. However, recent data published by various groups have challenged this. Specifically for the NACP-02 chamber, non-unity electron perturbation factors have already been published by Verhaegen et al (2006 Phys. Med. Biol. 51 1221-35) and Buckley and Rogers (2006 Med. Phys. 33 1788-96). Recently it was found that the mass thickness of the front chamber window can be 35% greater than is listed in the IAEA's TRS-398 absorbed dose protocol (Chin et al 2008 Phys. Med. Biol. 53 N119-26). This study therefore recalculated NACP-02 electron perturbation correction factors for energies 4-18 MeV at depths z(ref) and R(50) to determine the effect of the chamber model change. Results showed that perturbation factors at z(ref) are fairly stable for similar chamber models but become highly sensitive to small changes at deeper depths. The results also showed some dependence on using 1 keV versus 10 keV for the transport cut-off. Additional investigations revealed that the wall perturbation factor, p(wall), is strongly influenced by the chamber back wall at z(ref) and at larger depths small changes in the positioning of the effective point of measurement cause large fluctuations in the final value. Finally, the cavity perturbation factor, p(cav), was found to be primarily influenced by electron backscatter.

Entities:  

Mesh:

Year:  2008        PMID: 19098357     DOI: 10.1088/0031-9155/54/2/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

Authors:  Frédéric Lacroix; Mathieu Guillot; Malcolm McEwen; Claudiu Cojocaru; Luc Gingras; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Simulation of large x-ray fields using independently measured source and geometry details.

Authors:  D Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

3.  Treatment head disassembly to improve the accuracy of large electron field simulation.

Authors:  Bruce A Faddegon; Daren Sawkey; Tuathan O'Shea; Malcolm McEwen; Carl Ross
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.