Literature DB >> 19098355

Delivery of modulated electron beams with conventional photon multi-leaf collimators.

Eric E Klein1, Maria Mamalui-Hunter, Daniel A Low.   

Abstract

Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of +/-2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.

Entities:  

Mesh:

Year:  2008        PMID: 19098355     DOI: 10.1088/0031-9155/54/2/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Treatment head disassembly to improve the accuracy of large electron field simulation.

Authors:  Bruce A Faddegon; Daren Sawkey; Tuathan O'Shea; Malcolm McEwen; Carl Ross
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

2.  Preliminary comparison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity.

Authors:  Olivier Blasi; Jonas D Fontenot; Robert S Fields; John P Gibbons; Kenneth R Hogstrom
Journal:  Radiat Oncol       Date:  2011-12-28       Impact factor: 3.481

3.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

Review 4.  Radiotherapy: Basic Concepts and Recent Advances.

Authors:  S R Mehta; V Suhag; M Semwal; N Sharma
Journal:  Med J Armed Forces India       Date:  2011-07-21

5.  Image-guided bolus electron conformal therapy - a case study.

Authors:  Omar A Zeidan; Bhavin D Chauhan; William W Estabrook; Twyla R Willoughby; Rafael R Manon; Sanford L Meeks
Journal:  J Appl Clin Med Phys       Date:  2010-10-07       Impact factor: 2.102

6.  History and Current State of Radiation Oncology Services and Practice in Jordan.

Authors:  Jamal Khader; Abdelatif Al Mousa; Samir Al-Kayed; Hana Mahasneh; Rasmi Mubaidin; Nabeel Al Nassir; Sami Khatib; Adnan Qasem; Inad Haddadin; Elayan Elayan; Sondos Al Khatib
Journal:  JCO Glob Oncol       Date:  2020-06

7.  Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator.

Authors:  Lihui Jin; Ahmed Eldib; Jinsheng Li; Ismail Emam; Jiajin Fan; Lu Wang; C-M Ma
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

8.  Design and production of 3D printed bolus for electron radiation therapy.

Authors:  Shiqin Su; Kathryn Moran; James L Robar
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

9.  Production of patient-specific electron beam aperture cut-outs using a low-cost, multi-purpose 3D printer.

Authors:  Steven Michiels; Bram Mangelschots; Robin De Roover; Cédric Devroye; Tom Depuydt
Journal:  J Appl Clin Med Phys       Date:  2018-07-26       Impact factor: 2.102

10.  Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes.

Authors:  Luca Labate; Daniele Palla; Daniele Panetta; Federico Avella; Federica Baffigi; Fernando Brandi; Fabio Di Martino; Lorenzo Fulgentini; Antonio Giulietti; Petra Köster; Davide Terzani; Paolo Tomassini; Claudio Traino; Leonida A Gizzi
Journal:  Sci Rep       Date:  2020-10-14       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.