Literature DB >> 19097224

3D cine displacement-encoded MRI of pulsatile brain motion.

Michaela Soellinger1, Andrea K Rutz, Sebastian Kozerke, Peter Boesiger.   

Abstract

Pulsatile brain motion is considered to be an important mechanical link between blood and cerebrospinal fluid (CSF) dynamics. Like many severe brain diseases, different types of hydrocephalus are associated with impairment of these dynamics. In this work a cine displacement-encoded imaging method employing stimulated echoes (DENSE) and a three-dimensional (3D) segmented echo-planar imaging (EPI) readout for brain motion measurements in all three spatial directions is presented. Displacement-encoded data sets of 12 healthy volunteers were analyzed with respect to reproducibility, periodicity, and intra- as well as intersubject physiological consistency. In addition, displacement values were compared with data derived from phase-contrast (PC) velocity measurements in a subset of all measured subjects. Using DENSE, displacements as low as 0.01 mm could be detected and observation of the 3D pulse pressure wave propagation was possible. Among other parameters, peak displacements in the central brain regions were measured: feet-head (FH): thalamus (0.13 +/- 0.01 mm); right-left (RL): thalamus (0.06 +/- 0.01 mm); and anterior-posterior (AP): caudate nucleus (0.05 +/- 0.01 mm).

Entities:  

Mesh:

Year:  2009        PMID: 19097224     DOI: 10.1002/mrm.21802

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Cerebrospinal fluid dynamics in the human cranial subarachnoid space: an overlooked mediator of cerebral disease. I. Computational model.

Authors:  Sumeet Gupta; Michaela Soellinger; Deborah M Grzybowski; Peter Boesiger; John Biddiscombe; Dimos Poulikakos; Vartan Kurtcuoglu
Journal:  J R Soc Interface       Date:  2010-03-17       Impact factor: 4.118

Review 2.  The future of ultra-high field MRI and fMRI for study of the human brain.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-28       Impact factor: 6.556

Review 3.  Impacting the effect of fMRI noise through hardware and acquisition choices - Implications for controlling false positive rates.

Authors:  Lawrence L Wald; Jonathan R Polimeni
Journal:  Neuroimage       Date:  2016-12-28       Impact factor: 6.556

4.  Revealing sub-voxel motions of brain tissue using phase-based amplified MRI (aMRI).

Authors:  Itamar Terem; Wendy W Ni; Maged Goubran; Mahdi Salmani Rahimi; Greg Zaharchuk; Kristen W Yeom; Michael E Moseley; Mehmet Kurt; Samantha J Holdsworth
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

5.  Flow induced by ependymal cilia dominates near-wall cerebrospinal fluid dynamics in the lateral ventricles.

Authors:  Bercan Siyahhan; Verena Knobloch; Diane de Zélicourt; Mahdi Asgari; Marianne Schmid Daners; Dimos Poulikakos; Vartan Kurtcuoglu
Journal:  J R Soc Interface       Date:  2014-03-12       Impact factor: 4.118

6.  Prospective motion correction enables highest resolution time-of-flight angiography at 7T.

Authors:  Hendrik Mattern; Alessandro Sciarra; Frank Godenschweger; Daniel Stucht; Falk Lüsebrink; Georg Rose; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-12-11       Impact factor: 4.668

7.  Noninvasive Assessment of Intracranial Pressure Status in Idiopathic Intracranial Hypertension Using Displacement Encoding with Stimulated Echoes (DENSE) MRI: A Prospective Patient Study with Contemporaneous CSF Pressure Correlation.

Authors:  A M Saindane; D Qiu; J N Oshinski; N J Newman; V Biousse; B B Bruce; J F Holbrook; B M Dale; X Zhong
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-28       Impact factor: 3.825

8.  A Method for Measuring Orientation Within a Magnetic Resonance Imaging Scanner Using Gravity and the Static Magnetic Field (VectOrient).

Authors:  Adam van Niekerk; Andre van der Kouwe; Ernesta Meintjes
Journal:  IEEE Trans Med Imaging       Date:  2017-01-25       Impact factor: 10.048

9.  Brain mechanical property measurement using MRE with intrinsic activation.

Authors:  John B Weaver; Adam J Pattison; Matthew D McGarry; Irina M Perreard; Jessica G Swienckowski; Clifford J Eskey; S Scott Lollis; Keith D Paulsen
Journal:  Phys Med Biol       Date:  2012-10-18       Impact factor: 3.609

Review 10.  Review of MR elastography applications and recent developments.

Authors:  Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2012-10       Impact factor: 4.813

View more