Literature DB >> 19097222

Aortic vessel wall magnetic resonance imaging at 3.0 Tesla: a reproducibility study of respiratory navigator gated free-breathing 3D black blood magnetic resonance imaging.

Stijntje D Roes1, Jos J M Westenberg, Joost Doornbos, Rob J van der Geest, Emmanuelle Angelié, Albert de Roos, Matthias Stuber.   

Abstract

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Entities:  

Mesh:

Year:  2009        PMID: 19097222      PMCID: PMC2635497          DOI: 10.1002/mrm.21798

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

1.  Cardiac imaging at 4 Tesla.

Authors:  L Dougherty; T J Connick; G Mizsei
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.

Authors:  R M Botnar; W Y Kim; P Börnert; M Stuber; E Spuentrup; W J Manning
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

3.  In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography.

Authors:  Z A Fayad; T Nahar; J T Fallon; M Goldman; J G Aguinaldo; J J Badimon; M Shinnar; J H Chesebro; V Fuster
Journal:  Circulation       Date:  2000-05-30       Impact factor: 29.690

4.  Multicontrast-weighted magnetic resonance imaging of atherosclerotic plaques at 3.0 and 1.5 Tesla: ex-vivo comparison with histopathologic correlation.

Authors:  Andreas Koops; Harald Ittrich; Susan Petri; Andrew Priest; Alexander Stork; Ute Lockemann; Gerhard Adam; Christoph Weber
Journal:  Eur Radiol       Date:  2006-04-27       Impact factor: 5.315

5.  Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls.

Authors:  Ioannis Koktzoglou; Debiao Li
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

6.  Assessment of the carotid artery by MRI at 3T: a study on reproducibility.

Authors:  Reza Alizadeh Dehnavi; Joost Doornbos; Jouke T Tamsma; Matthias Stuber; Hein Putter; Rob J van der Geest; Hildo J Lamb; Albert de Roos
Journal:  J Magn Reson Imaging       Date:  2007-05       Impact factor: 4.813

7.  Subclinical coronary and aortic atherosclerosis detected by magnetic resonance imaging in type 1 diabetes with and without diabetic nephropathy.

Authors:  Won Yong Kim; Anne Sofie Astrup; Matthias Stuber; Lise Tarnow; Erling Falk; René M Botnar; Cheryl Simonsen; Lotte Pietraszek; Peter R Hansen; Warren J Manning; Niels T Andersen; Hans-Henrik Parving
Journal:  Circulation       Date:  2006-12-26       Impact factor: 29.690

8.  Effects of lipid-lowering by simvastatin on human atherosclerotic lesions: a longitudinal study by high-resolution, noninvasive magnetic resonance imaging.

Authors:  R Corti; Z A Fayad; V Fuster; S G Worthley; G Helft; J Chesebro; M Mercuri; J J Badimon
Journal:  Circulation       Date:  2001-07-17       Impact factor: 29.690

9.  Optimized 3D bright blood MRI of aortic plaque at 3 T.

Authors:  Michael Markl; Patrick Dudler; Alex Fydrychowicz; Christoph Strecker; Cornelius Weiller; Jürgen Hennig; Andreas Harloff
Journal:  Magn Reson Imaging       Date:  2008-02-20       Impact factor: 2.546

10.  Reliability of aortic MRI at 3 Tesla in patients with acute cryptogenic stroke.

Authors:  A Harloff; P Dudler; A Frydrychowicz; C Strecker; A L Stroh; A Geibel; C Weiller; A Hetzel; J Hennig; M Markl
Journal:  J Neurol Neurosurg Psychiatry       Date:  2007-10-26       Impact factor: 10.154

View more
  7 in total

1.  Coupling of vessel wall morphology and function in the aorta and the carotid artery: an evaluation with MRI.

Authors:  Eleanore S J Kröner; Hildo J Lamb; Hans-Marc J Siebelink; Hein Putter; Rob J van der Geest; Ernst E van der Wall; Albert de Roos; Jos J M Westenberg
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-30       Impact factor: 2.357

2.  Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: Development and feasibility study on the thoracic aorta.

Authors:  Zhehao Hu; Anthony G Christodoulou; Nan Wang; Jaime L Shaw; Shlee S Song; Marcel M Maya; Mariko L Ishimori; Lindsy J Forbess; Jiayu Xiao; Xiaoming Bi; Fei Han; Debiao Li; Zhaoyang Fan
Journal:  Magn Reson Med       Date:  2020-04-16       Impact factor: 4.668

3.  Coronary artery distensibility assessed by 3.0 Tesla coronary magnetic resonance imaging in subjects with and without coronary artery disease.

Authors:  Sebastian Kelle; Allison G Hays; Glenn A Hirsch; Gary Gerstenblith; Julie M Miller; Angela M Steinberg; Michael Schär; John H Texter; Ernst Wellnhofer; Robert G Weiss; Matthias Stuber
Journal:  Am J Cardiol       Date:  2011-05-31       Impact factor: 2.778

Review 4.  Magnetic Resonance Imaging of Cardiovascular Function and the Brain: Is Dementia a Cardiovascular-Driven Disease?

Authors:  Albert de Roos; Jeroen van der Grond; Gary Mitchell; Jos Westenberg
Journal:  Circulation       Date:  2017-05-30       Impact factor: 29.690

Review 5.  Pediatric magnetic resonance angiography: to contrast or not to contrast.

Authors:  Erin K Opfer; Nathan S Artz; Grace S Mitchell; Sherwin S Chan
Journal:  Pediatr Radiol       Date:  2022-08-12

Review 6.  Vessel wall characterization using quantitative MRI: what's in a number?

Authors:  Bram F Coolen; Claudia Calcagno; Pim van Ooij; Zahi A Fayad; Gustav J Strijkers; Aart J Nederveen
Journal:  MAGMA       Date:  2017-08-14       Impact factor: 2.310

7.  On the impact of vessel wall stiffness on quantitative flow dynamics in a synthetic model of the thoracic aorta.

Authors:  Judith Zimmermann; Michael Loecher; Fikunwa O Kolawole; Kathrin Bäumler; Kyle Gifford; Seraina A Dual; Marc Levenston; Alison L Marsden; Daniel B Ennis
Journal:  Sci Rep       Date:  2021-03-23       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.