AIM: To evaluate the usefulness of (99m)Tc-Sulphur colloid when combined with leukocyte scintigraphy in suspected prosthetic hip infection, comparing the results with information from (99m)Tc-HMPAO-leukocyte scintigraphy alone.
MATERIALS AND METHODS: Seventy patients (42 women, 28 men; mean age 68 +/- 13 years) with painful hip prostheses and suspicion of infection were evaluated prospectively. All patients had bone scintigraphy, (99m)Tc-HMPAO-labelled white blood cell scintigraphy and (99m)Tc-Sulphur colloid bone marrow scintigraphy. ESR and CRP levels were measured in all patients. The final diagnosis was made with microbiological findings or by clinical follow up of at least 12 months.
RESULTS: Infections were diagnosed in 12 of the 70 patients (3 coagulase-negative Staphylococcus, 2 Staphylococcus aureus, 2 Staphylococcus epidermidis, 2 enterococcus and 3 polymicrobial agents). ESR and CRP values were higher in patients with infection than in patients without infection (51.8 +/- 29.4 vs. 25.4 +/- 16.4 and 2.8 +/- 2.2 vs. 1.1 +/- 1.3, respectively; p < 0.05). Bone scintigraphy did not show a characteristic pattern to differentiate infection from aseptic loosening. The pool phase of the bone scintigraphy was positive in only 3/12 patients with infection (25 %). Sensitivity and specificity of the leukocyte scintigraphy was 83 % and 57 %, respectively. When the results of the bone marrow scintigraphy were added, these values increased to 92 % and 98 %, respectively.
CONCLUSION: Performing bone marrow scintigraphy significantly improves results when compared with leukocyte scintigraphy alone in the diagnosis of infected hip prostheses. Bone scintigraphy did not help to differentiate aseptic loosening from infection in this series.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19094902

Source DB:  PubMed          Journal:  Rev Esp Med Nucl        ISSN: 0212-6982


  3 in total

Review 1.  Prosthetic joint infections: radionuclide state-of-the-art imaging.

Authors:  Filip Gemmel; Hans Van den Wyngaert; Charito Love; M M Welling; Paul Gemmel; Christopher J Palestro
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-02-24       Impact factor: 9.236

2.  Dual-tracer approach vs. dual time-point approach in leukocyte scintigraphy in treatment evaluation of persistent chronic prosthetic joint infection.

Authors:  Johan Teiler; Börje Åkerlund; Harald Brismar; Irina Savitcheva; Marcus Ahl; Annie Bjäreback; Håkan Hedlund; Maria Holstensson; Rimma Axelsson
Journal:  Nucl Med Commun       Date:  2021-07-01       Impact factor: 1.690

3.  One-stage revision arthroplasty for infected hip replacements.

Authors:  Ernesto Muñoz-Mahamud; Xavier Gallart; Alejandro Soriano
Journal:  Open Orthop J       Date:  2013-06-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.