Literature DB >> 1909341

Stereospecific high-performance liquid chromatographic determination of tocainide.

R A Carr1, R T Foster, D Freitag, F M Pasutto.   

Abstract

A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence detection set at 220/345 nm (excitation/emission). The peaks, resolved with a resolution factor greater than 1.5, were free from interference. Linearity was established over the concentration range 0.25-10.0 mg/l for each enantiomer in plasma (r2 greater than 0.998). The inter-assay variability was less than 10% at all concentrations examined. The method can be used to determine the pharmacokinetics of tocainide enantiomers in man.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1909341     DOI: 10.1016/0378-4347(91)80120-2

Source DB:  PubMed          Journal:  J Chromatogr


  1 in total

1.  Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

Authors:  R A Carr; R T Foster; N H Bhanji
Journal:  Pharm Res       Date:  1991-09       Impact factor: 4.200