Literature DB >> 19092669

Microbubble activity in miniaturized and in conventional extracorporeal circulation.

Daniele Camboni1, Sebastian Schmidt, Alois Philipp, Leopold Rupprecht, Assad Haneya, Thomas Puehler, Matthias Arlt, Michael Hilker, Christof Schmid.   

Abstract

Since the establishment of miniaturized extracorporeal circulation (mECC), there has been a great controversy about a possible increased risk of gaseous microembolism as compared to conventional extracorporeal circulation (cECC). From March 2005 to June 2006, a prospective, randomized study, comparing three different mECC (MECC, PRECiSe, Resting Heart) with a cECC (HL30 Maquet) was performed. Ninety-three patients undergoing elective bypass surgery were included. The amount and size of microbubbles during perfusion was detected in the arterial lines utilizing an ultrasound Doppler system. Clinical outcome was compared by evaluating the incidence of postoperative neuropsychological dysfunction, postoperative renal dysfunction and hospitalization as well as the 30-day mortality. The highest microbubble activity was measured in all devices during the first 10 minutes of extracorporeal circulation. The amount of microbubbles was lower in the Resting Heart system (p=0.01), equal in the MECC system (p=0.16) and higher using the PRECiSe system as compared to the cECC (p=0.002). The microbubble diameter did not differ between all groups (p=0.56). Postoperative neuropsychological dysfunction (p=0.45), renal dysfunction (p=0.67), days of hospitalization (p=0.27), and 30 day-mortality (p=0.30) did not differ between all groups. A great variability in the occurrence of gaseous microemboli depending on the applied circuit exists. The Resting Heart system has lower, the MECC system an equal and the PRECiSe system depicted a higher activity in comparison to a cECC. The hypothesis about an increased risk in mECC in comparison to cECC with regard to microbubble activity is not supported by our results.

Entities:  

Mesh:

Year:  2009        PMID: 19092669     DOI: 10.1097/MAT.0b013e31818f3e8c

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

Review 1.  Use of minimal invasive extracorporeal circulation in cardiac surgery: principles, definitions and potential benefits. A position paper from the Minimal invasive Extra-Corporeal Technologies international Society (MiECTiS).

Authors:  Kyriakos Anastasiadis; John Murkin; Polychronis Antonitsis; Adrian Bauer; Marco Ranucci; Erich Gygax; Jan Schaarschmidt; Yves Fromes; Alois Philipp; Balthasar Eberle; Prakash Punjabi; Helena Argiriadou; Alexander Kadner; Hansjoerg Jenni; Guenter Albrecht; Wim van Boven; Andreas Liebold; Fillip de Somer; Harald Hausmann; Apostolos Deliopoulos; Aschraf El-Essawi; Valerio Mazzei; Fausto Biancari; Adam Fernandez; Patrick Weerwind; Thomas Puehler; Cyril Serrick; Frans Waanders; Serdar Gunaydin; Sunil Ohri; Jan Gummert; Gianni Angelini; Volkmar Falk; Thierry Carrel
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-01-26

2.  Conventional versus miniaturized cardiopulmonary bypass: A systematic review and meta-analysis.

Authors:  Timothy Cheng; Rajas Barve; Yeu Wah Michael Cheng; Andrew Ravendren; Amna Ahmed; Steven Toh; Christopher J Goulden; Amer Harky
Journal:  JTCVS Open       Date:  2021-10-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.