Literature DB >> 19092557

Real-time intraoperative computed tomography to assist cochlear implant placement in the malformed inner ear.

Jason D Bloom1, Mark D Rizzi, John A Germiller.   

Abstract

OBJECTIVE: Cochlear implantation is increasingly being performed in children with inner ear malformations. In severe cochleovestibular anomalies, such as severe partitioning defects and common cavity dysplasia, positioning of the electrode array can be hazardous, with inadvertent placement into the internal auditory canal (IAC) or carotid canal being well known. We describe a case in which real-time intraoperative computed tomographic scanning was used to help achieve proper electrode positioning in a child with a severe malformation. PATIENT: Child with common cavity malformations undergoing cochlear implantation. INTERVENTION: Intraoperative computed tomography used during implantation procedure. MAIN OUTCOME MEASURE: Use of technique in determining electrode position.
RESULTS: A 10-year-old patient with bilateral common cavity malformations presented with declining performance in a functioning implant placed 7 years earlier. The family elected implantation of the contralateral ear. Via a posterior labyrinthotomy approach, a straight array was placed into the common cavity. Intraoperative computed tomographic scanning was immediately performed on the operating room table, showing that the array was in the IAC. A second attempt with a different insertion angle also resulted in IAC placement. In a third attempt, the electrode was advanced as a loop, grasping the tip through an adjacent second labyrinthotomy. Computed tomography confirmed good position against the outer wall of the cavity.
CONCLUSION: Real-time intraoperative computed tomography is a new technology with many potential applications in surgery. In our patient, it allowed rapid and accurate determination of electrode position and helped achieve ideal placement in a severely malformed inner ear.

Entities:  

Mesh:

Year:  2009        PMID: 19092557     DOI: 10.1097/MAO.0b013e31818d1cd2

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  5 in total

Review 1.  [Surgical technique in cochlear implantation].

Authors:  M Praetorius; H Staecker; P K Plinkert
Journal:  HNO       Date:  2009-07       Impact factor: 1.284

2.  Extra-Cochlear Insertion in Cochlear Implantation: A Potentially Disastrous Condition.

Authors:  Emine Deniz Gözen; Fırat Tevetoğlu; Haydar Murat Yener; Eyüp Kara; Ahmet Ataş; Sabri Şirolu; Osman Kızılkılıç; Harun Cansız; Emin Karaman
Journal:  J Int Adv Otol       Date:  2019-12       Impact factor: 1.017

3.  Comparison of Intraoperative Portable CT Scanners in Skull Base and Endoscopic Sinus Surgery: Single Center Case Series.

Authors:  David B Conley; Bruce Tan; Bernard R Bendok; H Hunt Batjer; Rakesh Chandra; Douglas Sidle; Rudy J Rahme; Joseph G Adel; Andrew J Fishman
Journal:  Skull Base       Date:  2011-07

4.  Auditory Brainstem Implant Array Position Varies Widely Among Adult and Pediatric Patients and Is Associated With Perception.

Authors:  Samuel R Barber; Elliott D Kozin; Aaron K Remenschneider; Sidharth V Puram; Max Smith; Barbara S Herrmann; Mary E Cunnane; M Christian Brown; Daniel J Lee
Journal:  Ear Hear       Date:  2017 Nov/Dec       Impact factor: 3.570

5.  [Cochlear implant for malformations of the inner ear].

Authors:  A Aschendorff; R Laszig; W Maier; R Beck; C Schild; R Birkenhäger; T Wesarg; S Kröger; S Arndt
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

  5 in total