| Literature DB >> 19089220 |
Fernanda Brandão Mollica1, Fernanda Pelogia Camargo, Sandra Costa Zamboni, Sarina Maciel Braga Pereira, Symone Cristina Teixeira, Lafayette Nogueira.
Abstract
The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4 Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by one-way ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C (+/-0.56) for Group I, 0.84 degrees C (+/-0.55) for Group II, and 3.00 degrees C (+/- 1.34) for Group III. There were no statistically significant differences (p>0.05) between Groups I and II, but both of them differed significantly from Group III (p<0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.Entities:
Mesh:
Year: 2008 PMID: 19089220 PMCID: PMC4327696 DOI: 10.1590/s1678-77572008000300009
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Figure 1Different types of CVD ultrasound tips. A- Spherical. B- Truncated cone
Mean temperature increases and Tukey test (°C) for the experimental groups
| Groups | mean±sd(°C) | Homogeneous groups |
|---|---|---|
| High speed bur | 1.10±0.56 | A |
| Er:YAG Laser | 0.84±0.55 | A |
| CVDentus ultrasound tips | 3.00±1.34 | B |
means in the same column followed by the same letter do not differ from each other (Tukey test; p<0.05).
FIGURE 2Dot plot (around the mean value) and bar columns (mean±sd) for temperature rise data (°C) by groups