Literature DB >> 19088532

Cardiac tamponade caused by fracture and migration of inferior vena cava filter.

Preeti A Chandra1, Chibuzo Nwokolo, Dmitry Chuprun, Abhinav B Chandra.   

Abstract

A 53-year-old male presented to the emergency room with acute cardiopulmonary compromise. Echocardiography revealed cardiac tamponade. The patient was taken emergently for surgery and a 28 gauge wire of 1.5 cm was retrieved from his right ventricle. A section had fractured from the inferior vena cava (IVC) filter and migrated to the right ventricle, causing perforation and tamponade. Very few cases of fractured IVC filters that have migrated to the heart, and even fewer cases causing cardiac tamponade, have been described. The risk factors that cause migration of IVC filters need to be further elucidated.

Entities:  

Mesh:

Year:  2008        PMID: 19088532     DOI: 10.1097/SMJ.0b013e318172dd80

Source DB:  PubMed          Journal:  South Med J        ISSN: 0038-4348            Impact factor:   0.954


  10 in total

1.  Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience.

Authors:  Kevin P Cohoon; Joseph McBride; Jeremy L Friese; Ian R McPhail
Journal:  Catheter Cardiovasc Interv       Date:  2015-08-10       Impact factor: 2.692

Review 2.  Caval thrombus in conjunction with renal tumors: indication for surgery and technical details.

Authors:  J González; G Ciancio
Journal:  Curr Urol Rep       Date:  2014-11       Impact factor: 3.092

3.  Migration of a fractured inferior vena cava filter strut to the right ventricle of the heart.

Authors:  Zeyad Sako; Sindhu Reddy Avula; Elissa Gaies; Rebecca Daniel
Journal:  BMJ Case Rep       Date:  2018-03-21

4.  [Vena cava filters in trauma patients].

Authors:  D Baschera; J Sebunya; C Walter; R Zellweger
Journal:  Unfallchirurg       Date:  2010-09       Impact factor: 1.000

5.  IVC filter retrieval in adolescents: experience in a tertiary pediatric center.

Authors:  Anthony K Guzman; Mahmoud Zahra; Scott O Trerotola; Leslie J Raffini; Maxim Itkin; Marc S Keller; Anne Marie Cahill
Journal:  Pediatr Radiol       Date:  2016-01-21

6.  Fracture of a Tempofilter II: an initial case report.

Authors:  Hyung Jun Kim; Nam Kyu Chang; Jae Hoon Lim; Jae Kyu Kim
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

7.  Intracardiac embolization of inferior vena cava filter associated with right atrium perforation and cardiac tamponade.

Authors:  Alexandre de Matos Soeiro; Felipe Lourenço Fernandes; Rafael Plens Teixeira; Pedro Felipe Gomez Nicz; Maria Carolina Feres de Almeida Soeiro; Carlos V Serrano; Múcio Tavares de Oliveira
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Apr-Jun

8.  A Novel Source of Chest Pain in the Emergency Department.

Authors:  Ibrahim Isa; Jeffrey S Bush; Simon Watson; Joseph Schoepf
Journal:  Clin Pract Cases Emerg Med       Date:  2017-03-14

9.  Migration of a fractured inferior vena cava filter strut to the right ventricle of the heart: a case report.

Authors:  Hani Shennib; Bradley Bowles; Kelli Hickle
Journal:  J Cardiothorac Surg       Date:  2014-12-14       Impact factor: 1.637

10.  Cardiac Tamponade Due to Inferior Vena Cava Filter Removal: A Case Report and Review of Literature.

Authors:  Sohaib Roomi; Shujaul Haq; Waqas Ullah; Munnam S Jafar; Mahnoor Sherazi
Journal:  Cureus       Date:  2020-02-14