Literature DB >> 19085942

Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.

J M González-Méijome1, A López-Alemany, J B Almeida, M A Parafita.   

Abstract

PURPOSE: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure.
METHODS: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared between worn and unworn samples.
RESULTS: The quantitative parameters derived from the dehydration curves showed statistically significant differences between worn and unworn lenses regarding the initial dehydration rate and ability to maintain their original hydration. Worn lenses showed shorter phase I duration (decreased by 30 to 60% compared to unworn samples), a significantly faster initial dehydration rate (increased by about 1%/minute), and lower water retention index (decreased by 10 to 20%) as derived from the initial cumulative dehydration. All the differences were statistically significant for all lenses (p < 0.05).
CONCLUSION: The initial dehydration rates were significantly increased in all CL after wear. This could be of clinical interest because it represents the average initial dehydration rates during the first moments when the lens is left to dehydrate after a blink. This study suggests that even after the lenses had been equilibrated in saline solution for several days, the materials lose their ability to retain water. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19085942     DOI: 10.1002/jbm.b.31279

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  2 in total

1.  Comparison of tear osmolarity and ocular comfort between daily disposable contact lenses: hilafilcon B hydrogel versus narafilcon A silicone hydrogel.

Authors:  Ozge Sarac; Canan Gurdal; Basak Bostancı-Ceran; Izzet Can
Journal:  Int Ophthalmol       Date:  2012-04-07       Impact factor: 2.031

2.  Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.

Authors:  Nery García-Porta; Laura Rico-del-Viejo; Helena Ferreira-Neves; Sofia C Peixoto-de-Matos; Antonio Queirós; José M González-Méijome
Journal:  Biomed Res Int       Date:  2015-03-31       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.