Standardization of the INR: how good is your laboratory's INR and can it be improved?

Emmanuel J Favaloro1, Dorothy M Adcock.   

Abstract

The prothrombin time (PT) assay is the most clinically ordered coagulation test and is most often used for monitoring of vitamin K antagonist (VKA) therapy (e.g., warfarin), where results are expressed as an international normalized ratio (INR). The INR is in essence the patient's PT "mathematically adjusted" to a standardized value by taking into account the peculiarities of the test system through applying two "correction factors" defined by an international sensitivity index (ISI) and mean normal prothrombin time (MNPT). Although some manufacturers provide assigned ISI values for specific PT reagents and instrumentation, it is still recommended practice that laboratories check or locally validate these ISIs, as well as estimate the MNPT based on the population being tested. Where a manufacturer does not provide an ISI, the laboratory needs to define its own (local ISI) value. Current recommendations suggest the use of commercial reference-plasma calibration sets, but there is limited information to validate their performance in laboratory practice. We report our personal experience with use of some of these materials, as well as review alternate or supplementary procedures for calibration and/or validation of ISI and for determination and validation of MNPT. In brief, our data and experience suggests that further verification checks should be performed prior to acceptance of ISI and MNPT estimates generated from commercial reference-plasma calibration sets. We detail various strategies to ensure that laboratory practices are optimized to provide INRs that accurately reflect a patient's true anticoagulant status and to thus assist their clinical therapeutic management.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19085760     DOI: 10.1055/s-0028-1104538

Source DB:  PubMed          Journal:  Semin Thromb Hemost        ISSN: 0094-6176            Impact factor:   4.180


  3 in total

1.  Evaluation of the Steelex M600H coagulometer prothrombin time-international normalized ratio assay with Steelex test reagents.

Authors:  Yasemin U Budak; Kağan Huysal; Murat Polat; Gülsevil Tarakçi; Hakan Uçar
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

2.  VKORC1 and CYP2C9 Genotype Variations in Relation to Warfarin Dosing in Korean Stroke Patients.

Authors:  Sea Mi Park; Jong-Keuk Lee; Sa Il Chun; Hae In Lee; Sun U Kwon; Dong-Wha Kang; Jong S Kim
Journal:  J Stroke       Date:  2013-05-31       Impact factor: 6.967

Review 3.  The new oral anticoagulants and the future of haemostasis laboratory testing.

Authors:  Emmanuel J Favaloro; Giuseppe Lippi
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.