Literature DB >> 19085496

Reduced variability in cup positioning: the direct anterior surgical approach using navigation.

Michael Nogler1, Eckart Mayr, Martin Krismer, Martin Thaler.   

Abstract

BACKGROUND AND
PURPOSE: Correct positioning of the acetabular component is important in total hip arthroplasty (THA). We evaluated the effect of an imageless navigation system on the accuracy of cup positioning using a minimally invasive direct anterior approach.
METHODS: Hip replacements were performed in 44 cadaveric hips (22 cadavers) that were divided randomly into 2 groups. In the study group, THA was performed using an imageless navigation system. In the control group, no navigation system was used. CT scans were taken postoperatively. Using 3D reconstructions, the cup position was determined in relation to the frontal pelvic plane. The goal was to place each cup at 45 degrees of inclination and 20 degrees of anteversion, as recommended by the manufacturer.
RESULTS: In the navigated group, there was a statistically significantly smaller range of deviation from the target angles of inclination and anteversion relative to the control group.
INTERPRETATION: We conclude that imageless navigation improves the accuracy of cup placement in minimally invasive THA using the direct anterior approach.

Entities:  

Mesh:

Year:  2008        PMID: 19085496     DOI: 10.1080/17453670810016867

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  5 in total

1.  Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Authors:  Weifeng Ji; Nathaniel Stewart
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

2.  The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital.

Authors:  Mark C Callanan; Bryan Jarrett; Charles R Bragdon; David Zurakowski; Harry E Rubash; Andrew A Freiberg; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  The Direct Anterior Approach Total Hip Arthroplasty Reliably Achieves "Safe Zones" for Combined Anteversion.

Authors:  J Benjamin Jackson; J Ryan Martin; Aric Christal; John L Masonis; Bryan D Springer; J Bohannon Mason
Journal:  Arthroplast Today       Date:  2020-08-22

4.  The distance of the gluteal nerve in relation to anatomical landmarks: an anatomic study.

Authors:  David Putzer; Matthias Haselbacher; Romed Hörmann; Martin Thaler; Michael Nogler
Journal:  Arch Orthop Trauma Surg       Date:  2017-11-25       Impact factor: 3.067

5.  A Surgeon's handedness in direct anterior approach-hip replacement.

Authors:  Xiangpeng Kong; Minzhi Yang; Alvin Ong; Renwen Guo; Jiying Chen; Yan Wang; Wei Chai
Journal:  BMC Musculoskelet Disord       Date:  2020-08-03       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.