Literature DB >> 19085172

Characterization of knee-thigh-hip response in frontal impacts using biomechanical testing and computational simulations.

Jonathan D Rupp1, Carl S Miller, Matthew P Reed, Nathaniel H Madura, Kathleen D Klinich, Lawrence W Schneider.   

Abstract

Development and validation of crash test dummies and computational models that are capable of predicting the risk of injury to all parts of the knee-thigh-hip (KTH) complex in frontal impact requires knowledge of the force transmitted from the knee to the hip under knee impact loading. To provide this information, the knee impact responses of whole and segmented cadavers were measured over a wide range of knee loading conditions. These data were used to develop and help validate a computational model, which was used to estimate force transmitted to the cadaver hip. Approximately 250 tests were conducted using five unembalmed midsize male cadavers. In these tests, the knees were symmetrically impacted with a 255-kg padded impactor using three combinations of knee-impactor padding and velocity that spanned the range of knee loading conditions produced in FMVSS 208 and NCAP tests. Each subject was tested in four conditions. Following test of whole seated cadavers, the subjects were impacted after the connection between the thigh flesh and pelvis was cut, after the thigh flesh was removed, and after the torso was removed. Applied force and femur and pelvis acceleration data from these tests and results of other studies were used with data on static body segment masses to develop and validate a one-dimensional lumped-parameter model of the body. Simulation of the whole body cadaver tests performed with this model predict that approximately 54% of the peak force applied to the knee was transmitted to the hip for all three impact velocities. Additional simulations with the model in which knee impact conditions were varied over a wider range of loading conditions indicate that the percentage drop in force between the knee and the hip is relatively constant over the range of knee impact conditions that are of interest for injury assessment. Simulation results also indicate that high-rate, short-duration knee loading by a rigid surface is more likely to produce knee/distal femur fractures and less likely to produce hip fractures due to laxity in the hip that delays recruitment of pelvis mass and the development of fracture-level forces at the hip until after the fracture tolerance of the knee/femur has been exceeded.

Entities:  

Mesh:

Year:  2008        PMID: 19085172     DOI: 10.4271/2008-22-0017

Source DB:  PubMed          Journal:  Stapp Car Crash J        ISSN: 1532-8546


  2 in total

Review 1.  Current state and progress of research on forensic biomechanics in China.

Authors:  Yijiu Chen
Journal:  Forensic Sci Res       Date:  2021-05-04

2.  Dynamic Response of the Thoracolumbar and Sacral Spine to Simulated Underbody Blast Loading in Whole Body Post Mortem Human Subject Tests.

Authors:  Donald Sherman; Karthik Somasundaram; Paul Begeman; Sierra Foley; Jason Greb; Cynthia Bir; Constantine K Demetropoulos; John M Cavanaugh
Journal:  Ann Biomed Eng       Date:  2021-03-15       Impact factor: 3.934

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.