Literature DB >> 19084668

Application of Chemcatcher passive sampler for monitoring levels of mercury in contaminated river water.

Rocío Aguilar-Martínez1, M Milagros Gómez-Gómez, Richard Greenwood, Graham A Mills, Branislav Vrana, María A Palacios-Corvillo.   

Abstract

A passive sampler (Chemcatcher) consisting of a 47 mm Emporetrade mark chelating disk (CHE) with iminodiacetic groups as the receiving phase overlaid with a diffusion membrane was developed and calibrated for the monitoring of Hg in water. Three different diffusion membranes including cellulose acetate (CA), polyethersulphone (PS) and cellulose dialysis membrane (D) were tested. The best performance was obtained with the CHE-PS tandem. The effective sampling rate of the device (R(s), L day(-1)) is defined as the equivalent volume of water extracted per unit time, and is analyte specific and can be determined experimentally in a flow-through tank. Effects of water temperature and turbulence on the uptake rate of Hg were assessed under controlled laboratory conditions. Sampling rates were in the range of 0.029-0.091 L day(-1). An increase in sampling rate with turbulence was demonstrated. The detection limit of the sampler obtained in flowing waters ranged between 2.2 and 2.9 ng L(-1)Hg. The performance of Chemcatcher was tested alongside spot water sampling in a 14-day field deployment at two locations on the Valdeazogues River, Almadén, Spain. In general, the Hg concentration estimated by the Chemcatcher was lower than that found in spot water samples collected over the same period. This may be explained by the behaviour of this sampler that measures only the labile fraction of Hg in water, and this will exclude some species. However, Chemcatcher preconcentrates Hg allowing its determination in some places where its concentration is below the detection limit of spot sampling.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19084668     DOI: 10.1016/j.talanta.2008.09.037

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Preliminary investigation of polymer-based in situ passive samplers for mercury and methylmercury.

Authors:  Vivien F Taylor; Kate L Buckman; Robert M Burgess
Journal:  Chemosphere       Date:  2019-06-18       Impact factor: 7.086

Review 2.  Overview of passive Chemcatcher sampling with SPE pretreatment suitable for the analysis of NPEOs and NPs.

Authors:  Heidi Ahkola; Sirpa Herve; Juha Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2012-09-15       Impact factor: 4.223

3.  Study of different Chemcatcher configurations in the monitoring of nonylphenol ethoxylates and nonylphenol in aquatic environment.

Authors:  Heidi Ahkola; Sirpa Herve; Juha Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2014-04-06       Impact factor: 4.223

  3 in total