Literature DB >> 19083885

Feasibility of gadolinium-diethylene triamine pentaacetic acid enhanced multidetector computed tomography for the evaluation of coronary artery disease.

Patricia Carrascosa1, Carlos Capuñay, Marcelo Bettinotti, Alejandro Goldsmit, Alejandro Deviggiano, Jorge Carrascosa, Mario J García.   

Abstract

BACKGROUND: Multidetector computed tomography (MDCT) has been proposed as a noninvasive method for the diagnosis of obstructive coronary artery disease (CAD). In patients with high risk of iodinated contrast adverse effects such as acute allergic-type reactions, the use of gadolinium could be an alternative.
OBJECTIVE: We sought to evaluate the feasibility of gadolinium-enhanced MDCT for the diagnosis of obstructive CAD.
METHODS: Twenty patients (mean age, 61 years; range, 50-73 years) referred for X-ray coronary angiography were studied by both gadolinium and iodine-enhanced 16-row MDCT coronary angiography. The degree of enhancement and the accuracy for detection of obstructive CAD (>50% diameter reduction) were evaluated with X-ray coronary angiography as the standard. Renal nephrotoxicity was strictly monitored.
RESULTS: Gadolinium- and iodine-enhanced MDCT showed adequate visualization of the coronary arteries in 310 of the 312 coronary artery segments that were available by X-ray angiography, respectively. The average density of the coronary arteries in both iodine and gadolinium CT scans was 253.65 Hounsfield unit (HU) and 135.20 HU, respectively. In a per-coronary segment analysis, gadolinium- and iodine-enhanced MDCT showed sensitivities of 89% vs 84%, specificities of 96% vs 95%, and negative predictive values of 97% vs 96%, respectively. In a per-patient analysis, both gadolinium- and iodine-enhanced MDCT showed sensitivities of 92.85% vs specificities of 83.33%. Intermethod agreement between gadolinium- and iodine-enhanced MDCT (kappa) was 0.95 (P < 0.0001).
CONCLUSION: Our preliminary results indicate lower attenuation with gadolinium but similar diagnostic accuracy for the detection of obstructive CAD when compared with iodine-enhanced MDCT. Therefore, gadolinium is a feasible alternative contrast agent for patients with iodine contrast allergy referred for MDCT coronary angiography.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 19083885     DOI: 10.1016/j.jcct.2007.06.003

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  5 in total

1.  Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

Authors:  Sabine Schueler; Stefan Walther; Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

2.  Advances in cardiac CT contrast injection and acquisition protocols.

Authors:  Jan-Erik Scholtz; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

3.  Gold nanoparticle contrast in a phantom and juvenile swine: models for molecular imaging of human organs using x-ray computed tomography.

Authors:  Evan Boote; Genevieve Fent; Vijaya Kattumuri; Stan Casteel; Kavita Katti; Nripen Chanda; Raghuraman Kannan; Kattesh Katti; Robert Churchill
Journal:  Acad Radiol       Date:  2010-04       Impact factor: 3.173

Review 4.  Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis.

Authors:  Peter Schlattmann; Georg M Schuetz; Marc Dewey
Journal:  Eur Radiol       Date:  2011-05-20       Impact factor: 5.315

Review 5.  Use of 3x2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies.

Authors:  Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  BMJ       Date:  2012-10-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.