Literature DB >> 19082184

Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction.

Martina O' Toole1, Leon Barron, Roderick Shepherd, Brett Paull, Pavel Nesterenko, Dermot Diamond.   

Abstract

The combination of post-column derivatisation and visible detection are regularly employed in ion chromatography (IC) to detect poorly absorbing species. Although this mode is often highly sensitive, one disadvantage is the increase in repeating baseline artifacts associated with out-of-sync pumping systems. The work presented here will demonstrate the use of a second generation design paired emitter-detector diode (PEDD-II) detection mode offering enhanced sensitivity to transition metals in IC by markedly reducing this problem and also by improving signal noise. First generation designs demonstrated the use of a single integrated PEDD detector cell as a simple, small (15 x 5 mm), highly sensitive, low cost photometric detector for the detection of metals in IC. The basic principle of this detection mode lies in the employment of two linear light emitting diodes (LEDs), one operating in normal mode as a light source and the other in reverse bias serving as a light detector. The second generation PEDD-II design showed increased sensitivity for Mn(II)- and Co(II)-2-(pyridylazo)resorcinol (PAR) complexes as a result of two simultaneously acquiring detection cells--one analytical PEDD cell and one reference PEDD cell. Therefore, the PEDD-II employs two wavelengths whereby one monitors the analyte reaction product and the second monitors a wavelength close to the isosbestic point. The optimum LED wavelength to be used for the analytical cell was investigated to maximise peak response. The fabrication process for both the analytical and reference PEDD cells was validated by determining the reproducibility of detectors within a batch. The reproducibility and sensitivity of the PEDD-II detector was then investigated using signals obtained from both intra- and inter-day chromatograms.

Entities:  

Year:  2008        PMID: 19082184     DOI: 10.1039/b812612g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  Miniaturized optical chemosensor for flow-based assays.

Authors:  Marta Pokrzywnicka; David J Cocovi-Solberg; Manuel Miró; Víctor Cerdà; Robert Koncki; Łukasz Tymecki
Journal:  Anal Bioanal Chem       Date:  2010-11-20       Impact factor: 4.142

2.  Towards optoelectronic urea biosensors.

Authors:  Marta Pokrzywnicka; Robert Koncki; Łukasz Tymecki
Journal:  Anal Bioanal Chem       Date:  2015-01-27       Impact factor: 4.142

3.  Advances in Optical Based Turbidity Sensing Using LED Photometry (PEDD).

Authors:  Cormac D Fay; Andrew Nattestad
Journal:  Sensors (Basel)       Date:  2021-12-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.