Literature DB >> 19079376

Computed tomography guided percutaneous transthoracic fine needle aspiration cytology in chest masses.

S B Basnet1, G B Thapa, R Shahi, M Shrestha, R Panth.   

Abstract

A retrospective, hospital based descriptive study was done to know the pathological spectrum of thoracic lesions and to correlate the radiological findings with cytological findings obtained from computed tomography guided percutaneous transthoracic fine needle aspiration of chest mass. The clinical, radiological and cytological data of 100 patients were studied who underwent CT guided FNAC from May, 2004 to May, 2007. Diagnostic accuracy of FNAC is 82%. Cytological examination showed that 51 cases were malignant and 31 cases were benign. Provisional diagnosis based on radiological findings were 50 and 32 cases of malignant and benign lesions respectively. Sensitivity and specificity, positive and negative predictive value of radiological findings in this study was 88%, 84%, 90% and 81% respectively. Post procedure complication were (a) pneumothorax in two cases and both the cases had to be hospitalized for active management (b) minimal perilesional hemorrhage and hemoptysis in three cases and (c) chest pain in six cases. CT guided FNAC is a simple and safe procedure with high diagnostic accuracy in the evaluation of focal chest lesions. Pneumothorax, perilesional hemorrhage, hemoptysis and chest pain are the usually encountered complications. Very few cases of complication require active management.

Entities:  

Mesh:

Year:  2008        PMID: 19079376

Source DB:  PubMed          Journal:  JNMA J Nepal Med Assoc        ISSN: 0028-2715            Impact factor:   0.406


  4 in total

1.  Comparison of FNAC smears, cytospin smears, and cellblocks of transthoracic guided FNAC of suspected lung tumor: A study of 100 cases.

Authors:  Ankur Singh Kshatriya; Pravina M Santwani
Journal:  J Cytol       Date:  2016 Jul-Sep       Impact factor: 1.000

2.  CT-guided fine-needle biopsy of focal lung lesions as the method for reducing the number of invasive diagnostic procedures.

Authors:  Anna Chodorowska; Adam Rzechonek; Tomasz Dyła; Beata Muszczyńska-Bernhard; Jarosław Adamek
Journal:  Pol J Radiol       Date:  2010-04

3.  Evaluation of precision of guidance techniques in image guided fine needle aspiration cytology of thoracic mass lesions.

Authors:  Shivani Kalhan; Pankaj Sharma; Sonia Sharma; Sharmila Dudani; Ts Ramakrishnan; Anupama Chowdhry
Journal:  J Cytol       Date:  2012-01       Impact factor: 1.000

4.  Computed tomogram guided fine-needle aspiration cytology of lung mass with histological correlation: A study in Eastern India.

Authors:  Santosh Kumar Mondal; Dipanwita Nag; Rama Das; Palash Kumar Mandal; Pranab Kr Biswas; Manish Osta
Journal:  South Asian J Cancer       Date:  2013-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.