Suitability of single tissue dielectric constant measurements to assess local tissue water in normal and lymphedematous skin.

Harvey N Mayrovitz1, Suzanne Davey, Elizabeth Shapiro.   

Abstract

Previous reports described the use of average tissue dielectric constant (TDC) measurements to assess local tissue water and its change. Our goal was to determine if a single TDC measurement could be used in place of the average of multiple measurements. The comparison criteria used to test this was the extent to which single and averaged measurements yielded similar TDC values in both normal and lymphedematous tissue. Measurements were made in two groups of women; a control group (n = 20) and a group with unilateral arm lymphedema (n = 10). In the control group, TDC was measured to multiple depths (0.5-5.0 mm) on both ventral forearms and to a depth of 2.5 mm on the lateral thorax on both body sides. In the lymphedematous group, TDC was measured on both ventral forearms to a depth of 2.5 mm. Results showed that the 95% confidence interval for differences between single and averaged TDC values was less than +/-1 TDC unit and that the limits of agreement between methods was less than +/-2.5 TDC units (+/-6.5%) for each condition, site and depth measured. This finding suggests that where this level of agreement is acceptable suitable clinical assessments can be made using a single TDC measurement.

Entities:  

Mesh:

Year:  2008        PMID: 19076729     DOI: 10.1111/j.1475-097X.2008.00844.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  5 in total

1.  Function, Shoulder Motion, Pain, and Lymphedema in Breast Cancer With and Without Axillary Web Syndrome: An 18-Month Follow-Up.

Authors:  Linda A Koehler; David W Hunter; Anne H Blaes; Tufia C Haddad
Journal:  Phys Ther       Date:  2018-06-01

2.  Five-Year Cumulative Incidence of Axillary Web Syndrome and Comparison in Upper Extremity Movement, Function, Pain, and Lymphedema in Survivors of Breast Cancer With and Without Axillary Web Syndrome.

Authors:  Linda Koehler; Amanda Day; David Hunter; Anne Blaes; Tufia Haddad; Ryan Shanley
Journal:  Arch Phys Med Rehabil       Date:  2022-04-06       Impact factor: 4.060

3.  Tissue Dielectric Constant Measures in Women With and Without Clinical Trunk Lymphedema Following Breast Cancer Surgery: A 78-Week Longitudinal Study.

Authors:  Linda A Koehler; Harvey N Mayrovitz
Journal:  Phys Ther       Date:  2020-08-12

4.  Assessment of local tissue water in the arms and trunk of breast cancer survivors with and without upper extremity lymphoedema.

Authors:  Melissa Mazor; Betty J Smoot; Judy Mastick; Grace Mausisa; Steven M Paul; Kord M Kober; Charles Elboim; Komal Singh; Yvette P Conley; Gabby Mickevicius; Jennifer Field; Heather Hutchison; Christine Miaskowski
Journal:  Clin Physiol Funct Imaging       Date:  2018-09-12       Impact factor: 2.273

5.  Tissue Dielectric Constant of the Lower Leg as an Index of Skin Water: Temporal Variations.

Authors:  Harvey N Mayrovitz
Journal:  Cureus       Date:  2022-07-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.