Literature DB >> 19076180

The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw.

Alf Eliasson1, Ann Wennerberg, Anders Johansson, Anders Ortorp, Torsten Jemt.   

Abstract

BACKGROUND: New computer numeric controlled (CNC)-milled frameworks for implant-supported prostheses have been introduced. However, no data are available on the precision of fit of these new frameworks.
PURPOSE: The purpose of this study is to evaluate the precision of fit of a new CNC-milled framework technique (I-Bridge, Biomain AB, Helsingborg, Sweden) using Brånemark System (Nobel Biocare AB, Göteborg, Sweden) and NobelReplace (Nobel Biocare AB) system implants.
MATERIALS AND METHODS: Ten test frameworks were fabricated for one master model for each implant system. Five additional frameworks were fabricated for five different models simulating clinical cases as controls (Brånemark System). The distortion of implant center point positions was measured in x-, y-, and z-axes and in three dimensions by using a contact-type coordinate measuring machine and a computer program developed specifically for this purpose. Mann-Whitney U-test was used to compare differences of distortion within and between the groups.
RESULTS: The maximal distortion in arch width (x-axis) and curvature (y-axis) was within 71 and 55 microm for all frameworks, respectively. The mean distortion in absolute figures in x-, y-, z-axes and three dimensions was for "clinical control" frameworks 23, 26, 4, and 34 microm as compared with less than 12, 12, 2, and 17 microm for Brånemark and NobelReplace frameworks, respectively. Control frameworks showed significantly (p < .05) greater mean and range of distortions in x- and y-axes and in three dimensions compared with test frameworks.
CONCLUSION: All measured frameworks presented signs of misfit, indicating that no framework had a "passive fit." Frameworks produced in a more routine clinical environment seem to present greater levels of distortion as compared with frameworks produced in a strict test situation. However, all measured frameworks presented levels of precision of fit within limits considered to be clinically acceptable in earlier studies of frameworks placed on abutments.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19076180     DOI: 10.1111/j.1708-8208.2008.00131.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla.

Authors:  Lieven Barbier; Johan Abeloos; Calix De Clercq; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2011-09-20       Impact factor: 3.573

2.  Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report.

Authors:  Rubén Agustín-Panadero; David Peñarrocha-Oltra; Sonia Gomar-Vercher; Alberto Ferreiroa; Miguel Peñarrocha-Diago
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study.

Authors:  Adolfo Di Fiore; Lorenzo Graiff; Gianpaolo Savio; Stefano Granata; Michele Basilicata; Patrizio Bollero; Roberto Meneghello
Journal:  Int J Environ Res Public Health       Date:  2022-04-13       Impact factor: 4.614

4.  Four-year outcomes of full-arch fixed dental prostheses using CAD/CAM frameworks: A retrospective review of 15 cases.

Authors:  Ilser Turkyilmaz; Niki-Haj Hariri
Journal:  J Clin Exp Dent       Date:  2018-10-01

5.  Precision of fit of titanium and cast implant frameworks using a new matching formula.

Authors:  Marianella Sierraalta; Jose L Vivas; Michael E Razzoog; Rui-Feng Wang
Journal:  Int J Dent       Date:  2012-04-08

6.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20

7.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
  7 in total