Influence of source parameters on large-field electron beam profiles calculated using Monte Carlo methods.

Rebecca Weinberg1, John A Antolak, George Starkschall, Rajat J Kudchadker, R Allen White, Kenneth R Hogstrom.   

Abstract

The purpose of this paper was to study the source model for a Monte Carlo simulation of electron beams from a medical linear accelerator. In a prior study, a non-divergent Gaussian source with a full-width at half-maximum (FWHM) of 0.15 cm was successful in predicting relative dose distributions for electron beams with applicators. However, for large fields with the applicator removed, discrepancies were found between measured and calculated profiles, particularly in the shoulder region. In this work, the source was changed to a divergent Gaussian spatial distribution and the FWHM parameter was varied to produce better agreement with measured data. The influence of the FWHM source parameter on profiles was observed at multiple locations in the simulation geometry including in-air fluence profiles at a 95 cm source-to-surface distance (SSD), percent depth dose profiles and off-axis profiles (OARs) in a water phantom for two SSDs, 80 and 100 cm. For a 6 MeV 40 x 40 cm(2) OAR profile, discrepancies in the shoulder region were reduced from 15% to 4% using a FWHM value of 0.45 cm. The optimal FWHM values for the other energies were 0.45 cm for 9 MeV, 0.22 for 12 MeV, 0.25 for 16 MeV and 0.2 cm for 20 MeV. Although this range of values was larger than measured focal spot sizes reported by other researchers, using the increased FWHM values improved the fit at most locations in the simulation geometry, giving confidence that the model could be used with a variety of SSDs and field sizes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19075360     DOI: 10.1088/0031-9155/54/1/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Treatment head disassembly to improve the accuracy of large electron field simulation.

Authors:  Bruce A Faddegon; Daren Sawkey; Tuathan O'Shea; Malcolm McEwen; Carl Ross
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

2.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

3.  Comparison of measured Varian Clinac 21EX and TrueBeam accelerator electron field characteristics.

Authors:  Samantha A M Lloyd; Sergei Zavgorodni; Isabelle M Gagne
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102