Literature DB >> 19073120

Voltammetric behaviour of bromhexine and its determination in pharmaceuticals.

M Turchán1, P Jara-Ulloa, S Bollo, L J Nuñez-Vergara, J A Squella, A Alvarez-Lueje.   

Abstract

A complete electrochemical study and a novel electroanalytical procedure for bromhexine quantitation are described. Bromhexine in methanol/0.1molL(-1) Britton-Robinson buffer solution (2.5/97.5) shows an anodic response on glassy carbon electrode between pH 2 and 7.5. By DPV and CV, both peak potential and current peak values were pH-dependent in all the pH range studied. A break at pH 5.5 in E(P) versus pH plot revealing a protonation-deprotonation (pK(a)) equilibrium of bromhexine was observed. Spectrophotometrically, an apparent pK(a) value of 4.3 was also determined. An electrodic mechanism involving the oxidation of bromhexine via two-electrons and two-protons was proposed. Controlled potential electrolysis followed by HPLC-UV and GC-MS permitted the identification of three oxidation products: N-methylcyclohexanamine, 2-amino-3,5-dibromobenzaldehyde and 2,4,8,10-tetrabromo dibenzo[b,f][1,5] diazocine. DPV at pH 2 was selected as optimal pH for analytical purposes. Repeatability, reproducibility and selectivity parameters were adequate to quantify bromhexine in pharmaceutical forms. The recovery was 94.50+/-2.03% and the detection and quantitation limits were 1.4x10(-5) and 1.6x10(-5)molL(-1), respectively. Furthermore, the DPV method was applied successfully to individual tablet assay in order to verify the uniformity content of bromhexine. No special treatment of sample were required due to excipients do not interfered with the analytical signal. Finally the method was not time-consuming and less expensive than the HPLC one.

Entities:  

Year:  2007        PMID: 19073120     DOI: 10.1016/j.talanta.2007.05.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Development and characterization of molecularly imprinted polymers for controlled release of citalopram.

Authors:  Majid Abdouss; Ebadullah Asadi; Saman Azodi-Deilami; Neda Beik-mohammadi; Saeed Amir Aslanzadeh
Journal:  J Mater Sci Mater Med       Date:  2011-07-21       Impact factor: 3.896

2.  Electrodeposition of Cobalt Oxides on Carbon Nanotubes for Sensitive Bromhexine Sensing.

Authors:  Sireerat Lisnund; Vincent Blay; Pratchaya Muamkhunthod; Kittiya Thunyanon; Jaruwan Pansalee; Jirawan Monkrathok; Pachara Maneechote; Kantapat Chansaenpak; Piyanut Pinyou
Journal:  Molecules       Date:  2022-06-24       Impact factor: 4.927

3.  An electrochemical sensor based on poly(procaterol hydrochloride)/carboxyl multi-walled carbon nanotube for the determination of bromhexine hydrochloride.

Authors:  Dexian Kong; Libin Han; Zeming Wang; Lili Jiang; Qian Zhang; Qiong Wu; Jinwei Su; Chunhua Lu; Guonan Chen
Journal:  RSC Adv       Date:  2019-04-16       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.