Literature DB >> 19072036

Impedimetric aptasensor with femtomolar sensitivity based on the enlargement of surface-charged gold nanoparticles.

Chunyan Deng1, Jinhua Chen, Zhou Nie, Mengdong Wang, Xiaochen Chu, Xiaoli Chen, Xilin Xiao, Chunyang Lei, Shouzhuo Yao.   

Abstract

A simple and ultrasensitive label-free electrochemical impedimetric aptasensor for thrombin based on the cascaded signal amplification was reported. The sandwich system of aptamer/thrombin/aptamer-functionalized Au nanoparticles (Apt-AuNPs) was fabricated as the sensing platform. The change of the interfacial feature of the electrode was characterized by electrochemical impedance analysis with the redox probe [Fe(CN)(6)](3-/4-). For improving detection sensitivity, the three-level cascaded impedimetric signal amplification was developed: (1) Apt-AuNPs as the first-level signal enhancer; (2) the steric-hindrance between the enlarged Apt-AuNPs as the second-level signal amplification; (3) the electrostatic-repulsion between sodium dodecylsulfate (SDS) stabilized Apt-AuNPs and the redox probe [Fe(CN)(6)](3-/4-) as the third-level signal amplification. Enlargement of Apt-AuNPs integrated with negatively charged surfactant (SDS) capping could not only improve the detection sensitivity of the impedimetric aptasensor for thrombin but also present a simple and general signal-amplification model for impedimetric sensor. The aptasensor based on the enlargement of negatively charged Apt-AuNPs showed an increased response of the electron-transfer resistance to the increase of thrombin concentration through a wide detection range from 100 fM to 100 nM. The linear detection range was 0.05-35 nM, and thrombin was easily detectable to a concentration of 100 fM. The aptasensor also has good selectivity and reproducibility.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19072036     DOI: 10.1021/ac800958a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  9 in total

Review 1.  DNA diagnostics: nanotechnology-enhanced electrochemical detection of nucleic acids.

Authors:  Fang Wei; Peter B Lillehoj; Chih-Ming Ho
Journal:  Pediatr Res       Date:  2010-05       Impact factor: 3.756

2.  Aptamer-functionalized nano-biosensors.

Authors:  Tai-Chia Chiu; Chih-Ching Huang
Journal:  Sensors (Basel)       Date:  2009-12-21       Impact factor: 3.576

3.  A label-free electronic biosensor for detection of bone turnover markers.

Authors:  Yeo-Heung Yun; Amit Bhattacharya; Nelson B Watts; Mark J Schulz
Journal:  Sensors (Basel)       Date:  2009-10-12       Impact factor: 3.576

Review 4.  Design strategies for aptamer-based biosensors.

Authors:  Kun Han; Zhiqiang Liang; Nandi Zhou
Journal:  Sensors (Basel)       Date:  2010-05-04       Impact factor: 3.576

5.  DNA hybridization sensors based on electrochemical impedance spectroscopy as a detection tool.

Authors:  Jin-Young Park; Su-Moon Park
Journal:  Sensors (Basel)       Date:  2009-11-26       Impact factor: 3.576

Review 6.  Single-Stranded DNA Aptamers against Pathogens and Toxins: Identification and Biosensing Applications.

Authors:  Ka Lok Hong; Letha J Sooter
Journal:  Biomed Res Int       Date:  2015-06-23       Impact factor: 3.411

Review 7.  Label-Free Aptasensors for the Detection of Mycotoxins.

Authors:  Amina Rhouati; Gaelle Catanante; Gilvanda Nunes; Akhtar Hayat; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-12-18       Impact factor: 3.576

Review 8.  Bio-mimetic sensors based on molecularly imprinted membranes.

Authors:  Catia Algieri; Enrico Drioli; Laura Guzzo; Laura Donato
Journal:  Sensors (Basel)       Date:  2014-07-30       Impact factor: 3.576

Review 9.  Recent Advancements in the Technologies Detecting Food Spoiling Agents.

Authors:  Reena V Saini; Prachi Vaid; Neeraj K Saini; Samarjeet Singh Siwal; Vijai Kumar Gupta; Vijay Kumar Thakur; Adesh K Saini
Journal:  J Funct Biomater       Date:  2021-11-27
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.