Literature DB >> 19072028

Current practices in antinuclear antibody testing: results from the Belgian External Quality Assessment Scheme.

Marjan Van Blerk1, Christel Van Campenhout, Xavier Bossuyt, Jean Duchateau, René Humbel, Geneviève Servais, Jean-Paul Tomasi, Adelin Albert, Wim Coucke, Jean-Claude Libeer.   

Abstract

BACKGROUND: This study aimed to assess the state-of-the-art of antinuclear antibody (ANA) testing as practiced in the Belgian and Luxembourg laboratories, using the results obtained in the Belgian National External Quality Assessment Scheme from 2000 to 2005.
METHODS: During this period, nine samples with different specificities were sent for analysis. Participants were surveyed for methodology used and were asked to report staining pattern and titer of ANAs. In 2002, an attempt was made to improve the comparability of quantitative ANA results by the provision of a commercial reference material and to relate observed differences to methodology.
RESULTS: With one exception, all participants employed a microscope-based indirect immunofluorescence assay with human epithelial cell line 2 cells. Most laboratories were accurate in describing the pattern. The percentage of unacceptable answers was greater for samples with borderline levels of antibody and for samples showing a cytoplasmic pattern. An improvement in the detection of anticentromere antibodies was observed. For all samples, a wide range of titers was reported. The provision of the secondary reference preparation led to improved inter-laboratory concordance. Comparison of methodology variables revealed a correlation between unstandardized titers and the power of the lamp of the microscope and the use of a dark room.
CONCLUSIONS: The EQAS results presented in this work provide valuable insights into the state of the art of ANA testing as practiced in the Belgian and Luxembourg Laboratories and illustrate the important value of a national EQAS for ANA testing as a tool to improve performance and interlaboratory comparability of laboratory results.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19072028     DOI: 10.1515/CCLM.2009.021

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus.

Authors:  Chelsea Bentow; Gabriella Lakos; Rachel Rosenblum; Cassandra Bryant; Andrea Seaman; Michael Mahler
Journal:  Immunol Res       Date:  2015-02       Impact factor: 2.829

Review 2.  Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems.

Authors:  Luigi Cinquanta; Nicola Bizzaro; Giampaola Pesce
Journal:  Front Immunol       Date:  2021-02-25       Impact factor: 7.561

3.  ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study.

Authors:  Stefanie Van den Bremt; Sofie Schouwers; Marjan Van Blerk; Lieve Van Hoovels
Journal:  J Immunol Res       Date:  2017-02-21       Impact factor: 4.818

4.  Clinical relevance of HEp-2 indirect immunofluorescent patterns: the International Consensus on ANA patterns (ICAP) perspective.

Authors:  Jan Damoiseaux; Luis Eduardo Coelho Andrade; Orlando Gabriel Carballo; Karsten Conrad; Paulo Luiz Carvalho Francescantonio; Marvin J Fritzler; Ignacio Garcia de la Torre; Manfred Herold; Werner Klotz; Wilson de Melo Cruvinel; Tsuneyo Mimori; Carlos von Muhlen; Minoru Satoh; Edward K Chan
Journal:  Ann Rheum Dis       Date:  2019-03-12       Impact factor: 19.103

5.  Interpretation of ANA indirect immunofluorescence test outside the darkroom using NOVA view compared to manual microscopy.

Authors:  Susan S Copple; Troy D Jaskowski; Rashelle Giles; Harry R Hill
Journal:  J Immunol Res       Date:  2014-02-24       Impact factor: 4.818

Review 6.  Next-Generation Autoantibody Testing by Combination of Screening and Confirmation-the CytoBead® Technology.

Authors:  Mandy Sowa; Rico Hiemann; Peter Schierack; Dirk Reinhold; Karsten Conrad; Dirk Roggenbuck
Journal:  Clin Rev Allergy Immunol       Date:  2017-08       Impact factor: 8.667

  6 in total