Literature DB >> 19071825

Simultaneous determination of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry on a stannum film electrode.

Wei Wei Zhu1, Nian Bing Li, Hong Qun Luo.   

Abstract

A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at -1.4V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from -1.4 to -0.4V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 microg l(-1) for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results.

Entities:  

Year:  2007        PMID: 19071825     DOI: 10.1016/j.talanta.2007.04.055

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  7 in total

1.  Diagnostic assay of chromium (VI) in the ex vivo fluid of the urine of a smoker using a fluorine-doped handmade sensor.

Authors:  Suw Young Ly; Min Joon Kim
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

Review 2.  Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

Authors:  Anastasios Economou
Journal:  Sensors (Basel)       Date:  2018-03-29       Impact factor: 3.576

Review 3.  Thin Film Electrodes for Anodic Stripping Voltammetry: A Mini-Review.

Authors:  Bryan R Wygant; Timothy N Lambert
Journal:  Front Chem       Date:  2022-02-02       Impact factor: 5.221

4.  Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor.

Authors:  Suw Young Ly; Hai-Soo Yoo; Minki Jung; Kwang Hee Ko; Byung Jin Kim; Ki Chul Lee; Byung Min Choi
Journal:  Toxicol Res       Date:  2010-09

5.  Optimization of Stripping Voltammetric Sensor by a Back Propagation Artificial Neural Network for the Accurate Determination of Pb(II) in the Presence of Cd(II).

Authors:  Guo Zhao; Hui Wang; Gang Liu; Zhiqiang Wang
Journal:  Sensors (Basel)       Date:  2016-09-21       Impact factor: 3.576

6.  Direct Quantification of Cd2+ in the Presence of Cu2+ by a Combination of Anodic Stripping Voltammetry Using a Bi-Film-Modified Glassy Carbon Electrode and an Artificial Neural Network.

Authors:  Guo Zhao; Hui Wang; Gang Liu
Journal:  Sensors (Basel)       Date:  2017-07-03       Impact factor: 3.576

Review 7.  Electrochemical DNA Biosensors Based on Labeling with Nanoparticles.

Authors:  Christos Kokkinos
Journal:  Nanomaterials (Basel)       Date:  2019-09-23       Impact factor: 5.076

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.