Literature DB >> 19071772

A chemiluminescence sensor for the determination of hydrogen peroxide.

Azra Tahirović1, Amira Copra, Enisa Omanović-Miklicanin, Kurt Kalcher.   

Abstract

A chemiluminescence one-shot sensor for hydrogen peroxide is described. It is prepared by immobilization of cobalt chloride and sodium lauryl sulphate in hydroxyethyl cellulose matrix cast on a microscope cover glass. Luminol, sodium phosphate and the sample are mixed before use and applied on the membrane by a micropipette. The calibration graph is linear in the range 20-1600mug/L, and the detection limit of the method (3sigma) is 9mug/L. A relative standard deviation of 4.5% was obtained for 100mug/L H(2)O(2) (n=11). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater.

Entities:  

Year:  2007        PMID: 19071772     DOI: 10.1016/j.talanta.2007.01.072

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  7 in total

1.  Development of an ultrasound-enhanced smartphone colorimetric biosensor for ultrasensitive hydrogen peroxide detection and its applications.

Authors:  Kawin Khachornsakkul; Wijitar Dungchai
Journal:  RSC Adv       Date:  2020-06-26       Impact factor: 4.036

2.  Comparison of uric Acid quantity with different food in human urine by flow injection chemiluminescence analysis.

Authors:  Jiajia Wang; Xijuan Tan; Zhenghua Song
Journal:  J Anal Methods Chem       Date:  2013-10-22       Impact factor: 2.193

3.  An All-Glass Microfluidic Network with Integrated Amorphous Silicon Photosensors for on-Chip Monitoring of Enzymatic Biochemical Assay.

Authors:  Francesca Costantini; Roald M Tiggelaar; Riccardo Salvio; Marco Nardecchia; Stefan Schlautmann; Cesare Manetti; Han J G E Gardeniers; Giampiero de Cesare; Domenico Caputo; Augusto Nascetti
Journal:  Biosensors (Basel)       Date:  2017-12-05

4.  Hydrogen Peroxide Sensing Based on Inner Surfaces Modification of Solid-State Nanopore.

Authors:  Libo Zhu; Dejian Gu; Quanjun Liu
Journal:  Nanoscale Res Lett       Date:  2017-06-20       Impact factor: 4.703

5.  One pot fabrication of fluorescein functionalized manganese dioxide for fluorescence "Turn OFF-ON" sensing of hydrogen peroxide in water and cosmetic samples.

Authors:  Hassan Refat H Ali; Ahmed I Hassan; Yasser F Hassan; Mohamed M El-Wekil
Journal:  RSC Adv       Date:  2020-05-05       Impact factor: 4.036

6.  Modelling of impulsional pH variations using ChemFET-based microdevices: application to hydrogen peroxide detection.

Authors:  Abdou Karim Diallo; Lyes Djeghlaf; Jerome Launay; Pierre Temple-Boyer
Journal:  Sensors (Basel)       Date:  2014-02-19       Impact factor: 3.576

7.  In situ Immobilization of Copper Nanoparticles on Polydopamine Coated Graphene Oxide for H2O2 Determination.

Authors:  Yingzhu Liu; Yanwei Han; Rongsheng Chen; Haijun Zhang; Simin Liu; Feng Liang
Journal:  PLoS One       Date:  2016-07-05       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.