Literature DB >> 19071771

Speciation of chromium in natural waters by micropumping multicommutated light emitting diode photometry.

Cherrine K Pires1, Boaventura F Reis, Angel Morales-Rubio, Miguel de la Guardia.   

Abstract

A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100mm length and 2mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and determined as the difference between total Cr and Cr (VI). After carrying out the assays to select the best operational conditions the features of the method included: a linear response ranging from 10 to 200mugl(-1) Cr (III) and Cr (VI) (r=0.999, n=7); limits of detection of 2.05 and 1.0mugl(-1) for Cr (III) and Cr (VI), respectively; a relative standard deviation lower than 2.0% (n=20) for a typical solution containing 50mugl(-1) Cr; a sampling throughput of 67 and 105 determinations per hour for total Cr and Cr (VI), respectively, and recovery values within the range of 93-108% for spiked concentrations of the order of 50mugl(-1).

Entities:  

Year:  2007        PMID: 19071771     DOI: 10.1016/j.talanta.2007.01.044

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Flow-Injection Methods in Water Analysis-Recent Developments.

Authors:  Marek Trojanowicz; Marta Pyszynska
Journal:  Molecules       Date:  2022-02-19       Impact factor: 4.411

2.  A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step.

Authors:  Felisberto G Santos; Boaventura F Reis
Journal:  J Anal Methods Chem       Date:  2017-03-05       Impact factor: 2.193

3.  A Miniaturized Colorimeter with a Novel Design and High Precision for Photometric Detection.

Authors:  Jun-Chao Yan; Yan Chen; Yu Pang; Jan Slavik; Yun-Fei Zhao; Xiao-Ming Wu; Yi Yang; Si-Fan Yang; Tian-Ling Ren
Journal:  Sensors (Basel)       Date:  2018-03-08       Impact factor: 3.576

4.  A Robust Flow-Based System for the Spectrophotometric Determination of Cr(VI) in Recreational Waters.

Authors:  Tânia C F Ribas; Raquel B R Mesquita; Ana Machado; Joana L A Miranda; Graham Marshall; Adriano Bordalo; António O S S Rangel
Journal:  Molecules       Date:  2022-03-23       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.