Literature DB >> 19071769

Determination of polycyclic aromatic hydrocarbons (PAHs) in particulate matter collected with low volume samplers.

Paolo Bruno1, Maurizio Caselli, Gianluigi de Gennaro, Maria Tutino.   

Abstract

The determination of polycyclic aromatic hydrocarbons (PAHs) contained in samples of particulate matter (PM), collected with low volume pumps, were carried out with an high sensitivity method that comes from several revisions of a previous method. The present work describes how, by using programmable temperature vaporization (PTV) and a mass selective detector with inert ionic source for the GC-MS analysis and the modifications of microwave-assisted extraction (MAE), the sensitivity of the method can be increased. The PAHs chosen for testing the method are: benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1,2,3-cd]pyrene (Ip) and dibenzo[a,h]anthracene (DbA). They, in fact, belong to that group of substances that are the most harmful for human health for their carcinogenicity. PAHs recoveries for spiked standard solutions at different concentrations were between 95 and 100% with relative standard deviation ranging from 1 to 3%. The revised method was validated using a 1649a urban dust standard reference material (SRM). The results obtained were in good agreement with certified values. The high sensitivity of the method allows to carry out analyses using only a half of the sampled filter (usually 47mm diameter membranes). In this way, the other half can be used for the characterization of the other components of PM (heavy metals, organic carbon, ions, etc). The last step has been constituted by application of the optimized method on real samples collected in two cities located in Southern Italy (Bari and Taranto).

Entities:  

Year:  2007        PMID: 19071769     DOI: 10.1016/j.talanta.2007.01.043

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  The impact of infield biomass burning on PM levels and its chemical composition.

Authors:  P Dambruoso; G de Gennaro; A Di Gilio; J Palmisani; M Tutino
Journal:  Environ Sci Pollut Res Int       Date:  2013-12-06       Impact factor: 4.223

2.  Electrochemical Interrogation of G3-Poly(propylene thiophenoimine) Dendritic Star Polymer in Phenanthrene Sensing.

Authors:  Hlamulo R Makelane; Oluwakemi Tovide; Christopher E Sunday; Tesfaye Waryo; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2015-09-03       Impact factor: 3.576

3.  Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

Authors:  Gianluigi de Gennaro; Paolo Rosario Dambruoso; Alessia Di Gilio; Valerio Di Palma; Annalisa Marzocca; Maria Tutino
Journal:  Int J Environ Res Public Health       Date:  2015-12-24       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.