Literature DB >> 19071665

Pervaporation-flow injection with chemiluminescence detection for determination of iodide in multivitamin tablets.

D Nacapricha1, P Sangkarn, C Karuwan, T Mantim, W Waiyawat, P Wilairat, T Cardwell, I D McKelvie, N Ratanawimarnwong.   

Abstract

This paper describes the use of a pervaporation (PV) technique in a flow injection (FI) system for selective improvement in iodide analysis. Iodide in the sample zone is oxidized to iodine, which permeates through a hydrophobic membrane. Detection of the diffused iodine is achieved using the chemiluminescent (CL) emission at 425nm that results from the reaction between iodine and luminol. The method was applied for the analysis of some pharmaceutical products, such as nuclear emergency tablets and multivitamin tablets. Ascorbic acid present in multivitamin samples interfered seriously with the analysis, and off-line sample treatment using anion exchange resin was employed to successfully remove ascorbic acid before the analysis. Ascorbic acid was flushed from the column using 0.4M sodium nitrate followed by elution of iodide with 2M sodium nitrate. The detection limit (3S.D.) of the system was 0.5mgl(-1), with reproducibility of 5.2% R.S.D. at 5mgl(-1). Sample throughput was determined as 30injectionsh(-1). There was good agreement between iodide concentrations from extracted samples determined using four different methods, i.e., PV-FI, gas diffusion-flow injection, potentiometry and ICP-MS. A comparison of the analytical features of the developed pervaporation system with these of the previously reported chemiluminescence gas diffusion-flow injection previously reported is also described.

Entities:  

Year:  2007        PMID: 19071665     DOI: 10.1016/j.talanta.2006.11.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Determination of iodate in food, environmental, and biological samples after solid-phase extraction with Ni-Al-Zr ternary layered double hydroxide as a nanosorbent.

Authors:  Hossein Abdolmohammad-Zadeh; Keyvan Tavarid; Zeynab Talleb
Journal:  ScientificWorldJournal       Date:  2012-04-24

2.  Chip-Based Spectrofluorimetric Determination of Iodine in a Multi-Syringe Flow Platform with and without In-Line Digestion-Application to Salt, Pharmaceuticals, and Algae Samples.

Authors:  Joana L A Miranda; Raquel B R Mesquita; Edwin Palacio; José M Estela; Víctor Cerdà; António O S S Rangel
Journal:  Molecules       Date:  2022-02-16       Impact factor: 4.411

3.  In Situ Vapor Polymerization of Poly(3,4-ethylenedioxythiophene) Coated SnO₂-Fe₂O₃ Continuous Electrospun Nanotubes for Rapid Detection of Iodide Ions.

Authors:  Xiuru Xu; Wei Wang; Bolun Sun; Xue Zhang; Rui Zhao; Ce Wang
Journal:  Materials (Basel)       Date:  2018-10-24       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.