Literature DB >> 19071515

Determination of chromium(VI) and lead in water samples by on-line sorption preconcentration coupled with flame atomic absorption spectrometry using a PCTFE-beads packed column.

Aristidis N Anthemidis1, Salome-Juliette V Koussoroplis.   

Abstract

A new time-based flow injection on-line solid phase extraction method for chromium(VI) and lead determination using flame atomic absorption spectrometry was developed. The use of hydrophobic poly-chlorotrifluoroethylene (PCTFE)-beads as absorbent in on-line preconcentration system was evaluated. Effective formation of ammonium pyrrolidine dithiocarbamate complexes and subsequently retention in PCTFE packed column, was achieved in pH range 1.0-1.6 and 1.5-3.2 for Cr(VI) and Pb(II) ions, respectively. The sorbed analyte was efficiently eluted with isobutyl-methyl-ketone for on-line FAAS determination. The proposed packing material exhibited excellent chemical and mechanical resistance, fast kinetics for adsorption of Cr(VI) and Pb(II) permitting the use of high sample flow rates at least up to 15mLmin(-1) without loss of retention efficiency. For a preconcentration time of 90s, the sample frequency was 30h(-1), the enhancement factor was 94 and 220, the detection limit was 0.4 and 1.2mugL(-1), while the precision (R.S.D.) was 1.8% (at 5mugL(-1)) and 2.1% (at 30mugL(-1)) for chromium(VI) and lead, respectively. The applicability and the accuracy of the developed method were estimated by the analysis spiked water samples and certified reference material NIST-CRM 1643d (Trace elements in water) and NIST-SRM 2109 (chromium(VI) speciation in water).

Entities:  

Year:  2006        PMID: 19071515     DOI: 10.1016/j.talanta.2006.08.003

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A Novel Triazole Schiff Base Derivatives for Remediation of Chromium Contamination from Tannery Waste Water.

Authors:  Ahmad A Alluhaybi; Ahmed Alharbi; Ahmed M Hameed; Ayman A Gouda; Fatma S Hassen; Hassan S El-Gendy; Bahig M Atia; Amany R Salem; Mohamed A Gado; Antoaneta Ene; Hamdy A Awad; Hesham M H Zakaly
Journal:  Molecules       Date:  2022-08-10       Impact factor: 4.927

2.  Trace lead measurement and online removal of matrix interference in geosamples by ion-exchange coupled with flow injection and hydride generation atomic fluorescence spectrometry.

Authors:  Chun-Hua Tan; Xu-Guang Huang
Journal:  J Autom Methods Manag Chem       Date:  2009-09-06

3.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.