Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions.

Alfonso Berduque1, Yvonne H Lanyon, Valerio Beni, Grégoire Herzog, Yvonne E Watson, Kenneth Rodgers, Frank Stam, John Alderman, Damien W M Arrigan.   

Abstract

This paper describes the electrochemical characterisation of a range of gold and platinum microelectrode arrays (MEAs) fabricated by standard photolithographic methods. The inter-electrode spacing, geometry, numbers and dimensions of the electrodes in the arrays were found to influence the voltammetric behaviours obtained. Excellent correlation was found between experimental data and theoretical predictions employing published models of microelectrode behaviour. Gold MEAs were evaluated for their applicability to copper determination in a soil extract sample, where agreement was found between the standard analytical method and a method based on underpotential deposition-anodic stripping voltammetry (UPD-ASV) at the MEAs, offering a mercury-free alternative for copper sensing.

Entities:  

Year:  2006        PMID: 19071408     DOI: 10.1016/j.talanta.2006.05.090

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  Microfabricated FSCV-compatible microelectrode array for real-time monitoring of heterogeneous dopamine release.

Authors:  Matthew K Zachek; Jinwoo Park; Pavel Takmakov; R Mark Wightman; Gregory S McCarty
Journal:  Analyst       Date:  2010-05-13       Impact factor: 4.616

3.  Development of a Microelectrode Array Sensing Platform for Combination Electrochemical and Spectrochemical Aqueous Ion Testing.

Authors:  Robert D Gardner; Anhong Zhou; Nephi A Zufelt
Journal:  Sens Actuators B Chem       Date:  2009-02-02       Impact factor: 7.460

4.  Ultramicroelectrode array based sensors: a promising analytical tool for environmental monitoring.

Authors:  Jahir Orozco; César Fernández-Sánchez; Cecilia Jiménez-Jorquera
Journal:  Sensors (Basel)       Date:  2010-01-07       Impact factor: 3.576

Review 5.  Micro/Nano Electrode Array Sensors: Advances in Fabrication and Emerging Applications in Bioanalysis.

Authors:  Yang Liu; Xiuting Li; Jie Chen; Chonglin Yuan
Journal:  Front Chem       Date:  2020-11-13       Impact factor: 5.221

6.  Platinum-Based Interdigitated Micro-Electrode Arrays for Reagent-Free Detection of Copper.

Authors:  Robert Daly; Tarun Narayan; Han Shao; Alan O'Riordan; Pierre Lovera
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576