Literature DB >> 19071370

On-line stripping voltammetry of trace metals at a flow-through bismuth-film electrode by means of a hybrid flow-injection/sequential-injection system.

Anastasios Economou1, Anastasios Voulgaropoulos.   

Abstract

In this work, we describe an automated stripping analyzer operating on a hybrid flow-injection/sequential-injection (FIA/SIA) mode and utilizing a bismuth-film electrode (BiFE) as a flow-through sensor for on-line stripping voltammetry of trace metals. The instrument combines the advantages of FIA and SIA and is characterised by simplicity, low-cost, rapidity, versatility and low consumption of solutions. The proposed analytical flow methodology was applied to the determination of Cd(II) and Pb(II) by anodic stripping voltammetry (ASV) and of Ni(II) and Co(II) by adsorptive stripping voltammetry (AdSV). The steps of the rather complex experimental sequence (i.e. the bismuth-film formation, the analyte accumulation, the voltammetric stripping and the electrode cleaning/regeneration) were conducted on-line and the critical parameters related to the respective analytical procedures were investigated. In ASV, for a accumulation time of 180s the limits of detection for Cd(II) and Pb(II) were 2 and 1microg l(-1), respectively (S/N=3) and the relative standard deviations were 5.3% and 4.7%, respectively (n=8). In AdSV, for a total sample volume of 1000microl, the limits of detection for Ni(II) and Co(II) were 1microg l(-1) (S/N=3) and the relative standard deviations were 5.5% and 6.2%, respectively (n=8). The measurement frequency ranged between 15 and 20 stripping cycles h(-1). The results indicate that the BiFE is well suited as a flow-through detector for on-line stripping analysis and, by virtue of its low toxicity, can serve as a viable alternative to mercury-based flow-through electrodes.

Entities:  

Year:  2006        PMID: 19071370     DOI: 10.1016/j.talanta.2006.05.021

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Potentiometric Stripping Analysis of Cadmium and Lead with Constant Inverse Current in the Analytical Step Using an Open Tubular Mercury-Coated Glassy Carbon Electrode.

Authors:  Zvonimir J Suturović; Snežana Ž Kravić; Zorica S Stojanović; Ana D Đurović; Tanja Ž Brezo-Borjan
Journal:  J Anal Methods Chem       Date:  2019-04-02       Impact factor: 2.193

2.  Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE).

Authors:  Nahid Gharib Naseri; Sara J Baldock; Anastasios Economou; Nicholas J Goddard; Peter R Fielden
Journal:  Anal Bioanal Chem       Date:  2008-03-20       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.