Literature DB >> 19071328

Development of a one-step immunochromatographic strip test for the rapid detection of nevirapine (NVP), a commonly used antiretroviral drug for the treatment of HIV/AIDS.

M Pattarawarapan1, S Nangola, T R Cressey, C Tayapiwatana.   

Abstract

Currently, high-performance liquid chromatographic (HPLC) methods are mainly used to measure antiretroviral plasma concentrations in HIV-infected patients. Although the utility of routine therapeutic drug monitoring (TDM) as an additional tool to optimize long-term antiretroviral therapy is unclear, if TDM is to be widely used, the availability of simple, cheap and reliable methods for the measurement of antiretroviral drug levels are needed, particularly in resource-limited settings. In this study, an immunochromatograhic (IC) strip test to detect the presence of nevirapine (NVP) in body fluids has been developed. Antiserum to NVP was first raised in rabbits by immunization against NVP chemically conjugated with bovine serum albumin, and subsequently validated by Western immunoblotting and competitive indirect ELISA. The partially purified anti-NVP antibodies were conjugated with colloidal gold particles. The conjugation of the colloidal gold and polyclonal antibodies was monitored by UV-vis spectroscopy, while transmission electron microscopy images were used to characterize the particle size and shape of the conjugates. The resulting colloidal gold conjugates were used for the production of an IC strip test to detect nevirapine in human plasma. Preliminary assessment suggests no-cross reactivity of the NVP polyclonal antibodies but assessment of plasma samples from HIV-infected patients receiving HAART needs to be conducted. This assay could potentially be used for drug monitoring as part of the clinical care of HIV infected patients.

Entities:  

Year:  2006        PMID: 19071328     DOI: 10.1016/j.talanta.2006.05.059

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Immunochromatographic strip test for rapid detection of nevirapine in plasma samples from human immunodeficiency virus-infected patients.

Authors:  Tim R Cressey; Sawitree Nangola; Yardpiroon Tawon; Mookda Pattarawarapan; Marc Lallemant; Chatchai Tayapiwatana
Journal:  Antimicrob Agents Chemother       Date:  2007-07-02       Impact factor: 5.191

2.  Biosensing of DNA oxidative damage: a model of using glucose meter for non-glucose biomarker detection.

Authors:  Xuena Zhu; Mehenur Sarwar; Qiaoli Yue; Chunying Chen; Chen-Zhong Li
Journal:  Int J Nanomedicine       Date:  2017-02-02

Review 3.  Engineered CRISPR-Cas systems for the detection and control of antibiotic-resistant infections.

Authors:  Yuye Wu; Dheerendranath Battalapalli; Mohammed J Hakeem; Venkatarao Selamneni; Pengfei Zhang; Mohamed S Draz; Zhi Ruan
Journal:  J Nanobiotechnology       Date:  2021-12-04       Impact factor: 10.435

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.