Literature DB >> 19071307

Determination of bismuth and copper using adsorptive stripping voltammetry couple with continuous wavelet transform.

Shokooh S Khaloo1, Ali A Ensafi, T Khayamian.   

Abstract

A new method is proposed for the determination of bismuth and copper in the presence of each other based on adsorptive stripping voltammetry of complexes of Bi(III)-chromazorul-S and Cu(II)-chromazorul-S at a hanging mercury drop electrode (HMDE). Copper is an interfering element for the determination of Bi(III) because, the voltammograms of Bi(III) and Cu(II) overlapped with each other. Continuous wavelet transform (CWT) was applied to separate the voltammograms. In this regards, wavelet filter, resolution of the peaks and the fitness were optimized to obtain minimum detection limit for the elements. Through continuous wavelet transform Symlet4 (Sym4) wavelet filter at dilation 6, quantitative and qualitative analysis the mixture solutions of bismuth and copper was performed. It was also realized that copper imposes a matrix effect on the determination of Bi(III) and the standard addition method was able to cope with this effect. Bismuth does not have matrix effect on copper determination, therefore, the calibration curve using wavelet coefficients of CWT was used for determination of Cu(II) in the presence of Bi(III). The detection limits were 0.10 and 0.05ngml(-1) for bismuth and copper, respectively. The linear dynamic range of 0.1-30.0 and 0.1-32.0ngml(-1) were obtained for determination of bismuth in the presence of 24.0ngml(-1) of copper and copper in the presence of 24.0ngml(-1) of bismuth, respectively. The method was used for determination of these two cations in water and human hair samples. The results indicate the ability of method for the determination of these two elements in real samples.

Entities:  

Year:  2006        PMID: 19071307     DOI: 10.1016/j.talanta.2006.04.004

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  A Simple, Fast, and Inexpensive Simultaneous Determination of Trace Bismuth(III) and Lead(II) in Water Samples by Adsorptive Stripping Voltammetry.

Authors:  Malgorzata Grabarczyk; Marzena Adamczyk
Journal:  J Anal Methods Chem       Date:  2017-08-28       Impact factor: 2.193

2.  Simultaneous quantification of Bi(III) and U(VI) in environmental water samples with a complicated matrix containing organic compounds.

Authors:  Malgorzata Grabarczyk; Anna Koper
Journal:  Environ Monit Assess       Date:  2012-10-30       Impact factor: 2.513

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.