Literature DB >> 19071262

Comparison of different sorbents for multiresidue solid-phase extraction of 16 pesticides from groundwater coupled with high-performance liquid chromatography.

Angelo Antonio D'Archivio1, Maria Fanelli, Pietro Mazzeo, Fabrizio Ruggieri.   

Abstract

A procedure based on solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with diode array detection has been developed for the simultaneous analysis of 16 widely used pesticides in groundwater samples. The compounds analysed were: aldicarb, atrazine, desethylatrazine, desysopropylatrazine, carbofuran, 2,4-D, dicloran, fenitrothion, iprodione, linuron, metalaxyl, metazachlor, phenmedipham, procymidone, simazine and vinclozolin. Five different SPE sorbents, C(18) bonded silica (Isolute SPE C18 (EC)), graphitised carbon black (Superclean Envi-Carb), highly cross-linked polystyrene-divinylbenzene (Lichrolut EN), divinylbenzene-N-vinylpyrrolidone (Oasis HLB) and surface modified styrene-divinylbenzene (Strata X), were compared. HPLC separation and quantification of the selected pesticides was carried out under isocratic conditions by means of a new reversed-phase column (Gemini from Phenomenex) based on C(18) bonded to organic-silica particles. Oasis HLB and Strata X provided the best results in the preconcentration of 1-l samples, yielding average recoveries higher than 70%, except for phenmedipham that rapidly degrades in groundwater. Detection limits of the target pesticides provided by the proposed SPE-HPLC procedure were between 0.003 and 0.04microg l(-1).

Entities:  

Year:  2006        PMID: 19071262     DOI: 10.1016/j.talanta.2006.03.016

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Use of Fe₃O₄ Nanoparticles for Enhancement of Biosensor Response to the Herbicide 2,4-Dichlorophenoxyacetic Acid.

Authors:  Kee-Shyuan Loh; Yook Heng Lee; Ahmad Musa; Abdul Aziz Salmah; Ishak Zamri
Journal:  Sensors (Basel)       Date:  2008-09-18       Impact factor: 3.576

2.  Untargeted characterisation of dissolved organic matter contributions to rivers from anthropogenic point sources using direct-infusion and high-performance liquid chromatography/Orbitrap mass spectrometry.

Authors:  Jonathan A Pemberton; Charlotte E M Lloyd; Christopher J Arthur; Penny J Johnes; Michael Dickinson; Adrian J Charlton; Richard P Evershed
Journal:  Rapid Commun Mass Spectrom       Date:  2020-02-13       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.