Does computer-aided detection have a role in the arbitration of discordant double-reading opinions in a breast-screening programme?

J J James1, E J Cornford.   

Abstract

AIMS: To investigate whether a computer-aided detection (CAD) system could act as an arbitrator of discordant double-reading opinions, replacing the need for an independent third film reader.
METHODS: The mammograms of the 240 women that underwent arbitration by an independent third reader were identified from the 16,629 women attending our screening centre between July 2003 and April 2004. Mammograms of the arbitration cases were digitized and analysed by a CAD system. To assess the ability of CAD to act as the arbitrator, the site of the CAD prompts was retrospectively compared to the site of any abnormality noted by the original film readers. If a CAD prompt was placed on a region marked by one of the film readers then the decision of CAD as the arbitrator was that the women should be recalled for further assessment. If no mark was placed then the region was considered low risk and the decision was not to recall. The decision of CAD as the arbitrator was retrospectively compared with the original recall decision of the independent third reader.
RESULTS: There were 21 cancer cases in the group of women undergoing arbitration, diagnosed both at the original screening episode and subsequently. The independent third reader recalled 15/18 (83%) of the cancers that corresponded with the arbitrated lesion. CAD as the arbitrator would have recalled 16/18 (89%) of the cancers that corresponded to the arbitrated lesion. CAD acting as the arbitrator would have resulted in a significant increase in normal women being recalled to assessment in the arbitration group (P<0.001). The extra 50 recalls would have potentially increased the overall recall rate to assessment from 3.1 to 3.4%; a relative increase of 10%.
CONCLUSIONS: The main effect of CAD acting as an arbitrator of discordant double-reading opinions is to increase the recall rate, significantly above what is found when arbitration is performed by an independent third reader. Using CAD as an arbitrator may be an option to deal with discordant double-reading opinions when no other method of consensus or arbitration is available.

Entities:  

Mesh:

Year:  2008        PMID: 19070697     DOI: 10.1016/j.crad.2008.07.008

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Discrepant screening mammography assessments at blinded and non-blinded double reading: impact of arbitration by a third reader on screening outcome.

Authors:  Elisabeth G Klompenhouwer; Adri C Voogd; Gerard J den Heeten; Luc J A Strobbe; Vivianne C Tjan-Heijnen; Mireille J M Broeders; Lucien E M Duijm
Journal:  Eur Radiol       Date:  2015-04-18       Impact factor: 5.315

2.  On the role of arbitration of discordant double readings of screening mammography: experience from two Italian programmes.

Authors:  F Caumo; S Brunelli; E Tosi; S Teggi; C Bovo; G Bonavina; S Ciatto
Journal:  Radiol Med       Date:  2010-10-27       Impact factor: 3.469

Review 3.  Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review.

Authors:  Edward Azavedo; Sophia Zackrisson; Ingegerd Mejàre; Marianne Heibert Arnlind
Journal:  BMC Med Imaging       Date:  2012-07-24       Impact factor: 1.930