Literature DB >> 19070696

Quantitative assessment of first-pass perfusion of oesophageal squamous cell carcinoma using 64-section MDCT: initial observation.

T-W Chen1, Z-G Yang, Y Li, Z-L Li, J Yao, J-Y Sun.   

Abstract

AIM: To clarify the feasibility of first-pass perfusion computed tomography (CT) using 64-section multidetector CT (MDCT) for tumour microcirculation of oesophageal squamous cell carcinoma, and to determine the threshold value of first-pass perfusion values for the discrimination between the microcirculation of the tumour and normal oesophagus.
MATERIALS AND METHODS: Forty-one patients with pathologically confirmed oesophageal squamous cell carcinomas served as the test group, which was subdivided into subgroups according to the pathological grades or the status of lymph node metastasis. Forty patients with a normal oesophagus served as controls. All patients underwent volume-based perfusion imaging using 64-section MDCT. Perfusion parameters including perfusion (PF), peak enhancement (PE), blood volume (BV), and time to peak (TTP) were measured. The differences in perfusion parameters between the test and control groups, and between the subgroups were compared statistically. The cut-off values were obtained statistically to discriminate microcirculation between the tumour and normal oesophagus.
RESULTS: Mean values for the BV and TTP of the tumour were 12.57+/-5.15 ml/100g (range 2.9-25.6) and 33.71+/-14.12 s (range 6-65), respectively. Mean values for the BV and TTP of the normal oesophagus were 4.33+/-3.6 ml/100 g (range 0.3-11.7) and 24.15+/-11.67 s (range 6-48), respectively. The BV and TTP were statistically higher in the test group than in the control group (p<0.05), but no statistical differences in the PF and PE were found between the test and control groups (p>0.05). There were no statistical differences in all parameters between the subgroups of pathological grades, and between subgroups with and without lymph-node metastases (p>0.05). For the discrimination of microcirculation of the tumour from that of the normal oesophagus, a threshold BV value of 6.65 ml/100g was determined and achieved a sensitivity of 95.1%, and specificity of 90%.
CONCLUSION: The first-pass perfusion technique using 64-section MDCT could be valuable to assess the microcirculation of oesophageal squamous cell carcinomas.

Entities:  

Mesh:

Year:  2008        PMID: 19070696     DOI: 10.1016/j.crad.2008.06.005

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  8 in total

1.  CT Perfusion evaluation of gastric cancer: correlation with histologic type.

Authors:  Dong Ho Lee; Se Hyung Kim; Ijin Joo; Joon Koo Han
Journal:  Eur Radiol       Date:  2017-08-04       Impact factor: 5.315

2.  Value of two-phase dynamic multidetector computed tomography in differential diagnosis of post-inflammatory strictures from esophageal cancer.

Authors:  Grigory G Karmazanovsky; Svetlana A Buryakina; Evgeny V Kondratiev; Qin Yang; Dmitry V Ruchkin; Dmitry V Kalinin
Journal:  World J Gastroenterol       Date:  2015-08-07       Impact factor: 5.742

3.  Quantitative measurement of contrast enhancement of esophageal squamous cell carcinoma on clinical MDCT.

Authors:  Rui Li; Tian-Wu Chen; Li-Ying Wang; Li Zhou; Hang Li; Xiao-Li Chen; Chun-Ping Li; Xiao-Ming Zhang; Ru-Hui Xiao
Journal:  World J Radiol       Date:  2012-04-28

4.  Intravoxel incoherent motion diffusion-weighted imaging of resectable oesophageal squamous cell carcinoma: association with tumour stage.

Authors:  Yu-Cheng Huang; Tian-Wu Chen; Xiao-Ming Zhang; Nan-Lin Zeng; Rui Li; Yu-Lian Tang; Fan Chen; Yan-Li Chen
Journal:  Br J Radiol       Date:  2018-02-05       Impact factor: 3.039

5.  Computed tomography (CT) perfusion as an early predictive marker for treatment response to neoadjuvant chemotherapy in gastroesophageal junction cancer and gastric cancer--a prospective study.

Authors:  Martin Lundsgaard Hansen; Eva Fallentin; Carsten Lauridsen; Ian Law; Birgitte Federspiel; Lene Bæksgaard; Lars Bo Svendsen; Michael Bachmann Nielsen
Journal:  PLoS One       Date:  2014-05-20       Impact factor: 3.240

6.  The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

Authors:  Berhan Genc; Mecit Kantarci; Recep Sade; Ebru Orsal; Hayri Ogul; Aylin Okur; Yener Aydin; Leyla Karaca; Atilla Eroğlu
Journal:  Med Princ Pract       Date:  2016-01-19       Impact factor: 1.927

7.  Prediction of Treatment Outcome of Chemotherapy Using Perfusion Computed Tomography in Patients with Unresectable Advanced Gastric Cancer.

Authors:  Dong Ho Lee; Se Hyung Kim; Sang Min Lee; Joon Koo Han
Journal:  Korean J Radiol       Date:  2019-04       Impact factor: 3.500

8.  Assessing Microcirculation in Resectable Oesophageal Squamous Cell Carcinoma with Dynamic Contrast-enhanced MRI for Identifying Primary tumour and Lymphatic Metastasis.

Authors:  Yan-Li Chen; Yu Jiang; Tian-Wu Chen; Rui Li; Xiao-Ming Zhang; Fan Chen; Lan Wu; Jing Ou; Jian-Qiong Yang
Journal:  Sci Rep       Date:  2019-01-15       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.