Literature DB >> 19068494

Comparison of graft patency for off-pump and conventional coronary arterial bypass grafting using 64-slice multidetector spiral computed tomography angiography.

Changqing Gao1, Zhiyu Liu, Bojun Li, Cangsong Xiao, Yang Wu, Gang Wang, Li Yang, Guopeng Liu.   

Abstract

Off-pump coronary artery bypass graft surgery (OPCAB) has been performed for many years and its use is increasing frequently, but it remains an open question whether OPCAB provides similar patency to conventional coronary artery bypass graft (CCABG) surgery with cardiopulmonary bypass. The present study assessed the graft patency in patients that had coronary arterial bypass grafting (CABG) performed on-pump and off-pump. A total of 237 patients with CABG performed by a single surgeon were retrospectively studied, in which 100 patients underwent CCABG and 137 patients underwent OPCAB; the two groups were well matched according to relative factors and no significant differences were found in both groups. Postoperatively, systematic assessment on the graft patency of all the patients was conducted with 64-slice multidetector spiral computed tomography angiography (MSCTA) at one month, 1 year, 2 years, 3 years and 4 years, respectively, to provide 641 grafts for analysis. Patency of left internal mammary artery (LIMA) was higher than that of saphenous vein (SVG) in both groups; no significant difference was seen in LIMA patency and SVG patency in both groups. Results of 64-slice MSCTA indicate that OPCAB provides similar patency to CCABG surgery with CPB.

Entities:  

Mesh:

Year:  2008        PMID: 19068494     DOI: 10.1510/icvts.2008.195511

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  2 in total

1.  Development of a risk score for early saphenous vein graft failure: An individual patient data meta-analysis.

Authors:  Alexios S Antonopoulos; Ayodele Odutayo; Evangelos K Oikonomou; Marialena Trivella; Mario Petrou; Gary S Collins; Charalambos Antoniades
Journal:  J Thorac Cardiovasc Surg       Date:  2019-08-26       Impact factor: 5.209

2.  Eleven-year outcomes of U-clips in totally robotic coronary artery bypass grafting versus standard hand-sewn running suture in robotic-assisted coronary artery bypass grafting.

Authors:  Nan Cheng; Huajun Zhang; Ming Yang; Guopeng Liu; Yi Guo; Wenbin Kang; Changqing Gao; Rong Wang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-06-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.