Literature DB >> 19067202

Assessment of environmental impact on air quality by cement industry and mitigating measures: a case study.

G Kabir1, A I Madugu.   

Abstract

In this study, environmental impact on air quality was evaluated for a typical Cement Industry in Nigeria. The air pollutants in the atmosphere around the cement plant and neighbouring settlements were determined using appropriate sampling techniques. Atmospheric dust and CO2 were prevalent pollutants during the sampling period; their concentrations were recorded to be in the range of 249-3,745 mg/m3 and 2,440-2,600 mg/m3, respectively. Besides atmospheric dust and CO2, the air pollutants such as NOx, SOx and CO were in trace concentrations, below the safe limits approved by FEPA that are 0.0062-0.093 mg/m3 NOx, 0.026 mg/m3 SOx and 114.3 mg/m3 CO, respectively. Some cost-effective mitigating measures were recommended that include the utilisation of readily available and low-cost pozzolans material to produce blended cement, not only could energy efficiency be improved, but carbon dioxide emission could also be minimised during clinker production; and the installation of an advance high-pressure grinding rolls (clinker-roller-press process) to maximise energy efficiency to above what is obtainable from the traditional ball mills and to minimise CO2 emission from the power plant.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19067202     DOI: 10.1007/s10661-008-0660-4

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  3 in total

1.  Prevalence and determinants of mucous membrane irritations in a community near a cement factory in Zambia: a cross sectional study.

Authors:  Emmy Nkhama; Micky Ndhlovu; J Timothy Dvonch; Seter Siziya; Kuku Voyi
Journal:  Int J Environ Res Public Health       Date:  2015-01-16       Impact factor: 3.390

2.  Effects of Airborne Particulate Matter on Respiratory Health in a Community near a Cement Factory in Chilanga, Zambia: Results from a Panel Study.

Authors:  Emmy Nkhama; Micky Ndhlovu; J Timothy Dvonch; Mary Lynam; Graciela Mentz; Seter Siziya; Kuku Voyi
Journal:  Int J Environ Res Public Health       Date:  2017-11-06       Impact factor: 3.390

3.  Chronic cement dust load induce novel damages in foliage and buds of Malus domestica.

Authors:  Kamran Shah; Na An; Wenchun Ma; Gulshan Ara; Kawsar Ali; Svetlana Kamanova; Xiya Zuo; Mingyu Han; Xiaolin Ren; Libo Xing
Journal:  Sci Rep       Date:  2020-07-22       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.