Literature DB >> 19065006

The anisotropic compressive mechanical properties of the rabbit patellar tendon.

Lakiesha N Williams1, Steven H Elder, J L Bouvard, M F Horstemeyer.   

Abstract

In this study, we examine the transverse and longitudinal compressive mechanical behavior of the rabbit patellar tendon. The anisotropic compressive properties are of interest, because compression occurs where the tendon attaches to bone and where the tendon wraps around bone leading to the development of fibro-cartilaginous matrices. We quantified the time dependent viscoelastic and anisotropic behavior of the tendon under compression. For both orientations, sections of patellar tendon were drawn from mature male white New Zealand rabbits in preparation for testing. The tendons were sequentially compressed to 40% strain at strain rates of 0.1, 1 and 10% strain(s) using a computer-controlled stepper motor driven device under physiological conditions. Following monotonic loading, the tendons were subjected to stress relaxation. The tendon equilibrium compressive modulus was quantified to be 19.49+/-11.46 kPa for the transverse direction and 1.11+/-0.57 kPa for the longitudinal direction. The compressive modulus at applied strain rates of 0.1, 1 and 10% strain(s) in the transverse orientation were 13.48+/-2.31, 18.24+/-4.58 and 20.90+/-8.60 kPa, respectively. The compressive modulus at applied strain rates of 0.1, 1 and 10% strain/s in the longitudinal orientation were 0.19+/-0.11, 1.27+/-1.38 and 3.26+/-3.49 kPa, respectively. The modulus values were almost significantly different for the examination of the effect of orientation on the equilibrium modulus (p=0.054). Monotonic loading of the tendon showed visual differences of the strain rate dependency; however, no significant difference was shown in the statistical analysis of the effect of strain rate on compressive modulus. The statistical analysis of the effect of orientation on compressive modulus showed a significant difference. The difference shown in the orientation analysis validated the anisotropic nature of the tendon.

Entities:  

Mesh:

Year:  2008        PMID: 19065006

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  6 in total

1.  Interference screw fixation of free tendon grafts: significant time-dependent decrease of the initial contact forces.

Authors:  Christian Stärke; Ulrike Winkelmann; Siegmar Glüge; Roland Becker; Christoph H Lohmann; Uwe Winkelmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-11-28       Impact factor: 4.342

2.  Apparent transverse compressive material properties of the digital flexor tendons and the median nerve in the carpal tunnel.

Authors:  Erin K Main; Jessica E Goetz; M James Rudert; Curtis M Goreham-Voss; Thomas D Brown
Journal:  J Biomech       Date:  2010-12-30       Impact factor: 2.712

Review 3.  Pathogenesis of tendinopathies: inflammation or degeneration?

Authors:  Michele Abate; Karin Gravare Silbernagel; Carl Siljeholm; Angelo Di Iorio; Daniele De Amicis; Vincenzo Salini; Suzanne Werner; Roberto Paganelli
Journal:  Arthritis Res Ther       Date:  2009-06-30       Impact factor: 5.156

4.  Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching.

Authors:  Changcheng Shi; Sarah E Cisewski; P Darwin Bell; Hai Yao
Journal:  Ann Biomed Eng       Date:  2013-11-19       Impact factor: 3.934

5.  The mechanical properties of tibiofemoral and patellofemoral articular cartilage in compression depend on anatomical regions.

Authors:  Heng Li; Jinming Li; Shengbo Yu; Chengwei Wu; Wei Zhang
Journal:  Sci Rep       Date:  2021-03-17       Impact factor: 4.379

6.  The effect of constitutive representations and structural constituents of ligaments on knee joint mechanics.

Authors:  Gustavo A Orozco; Petri Tanska; Mika E Mononen; Kimmo S Halonen; Rami K Korhonen
Journal:  Sci Rep       Date:  2018-02-02       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.