Literature DB >> 19061166

Does an extra kidney-ureter-bladder radiograph taken in the upright position during routine intravenous urography provide diagnostic benefit?

Kamil Gürel1, Safiye Gürel, Melike Kalfaoğlu, Ozlem Yilmaz, Ahmet Metin.   

Abstract

PURPOSE: The aim of this prospective study was to assess the diagnostic benefit of taking a kidney-ureter-bladder (KUB) radiograph in an upright position during routine intravenous urography (IVU).
MATERIALS AND METHODS: Between February 2005 and September 2007, 170 consecutive patients were included in the study. A basal IVU exam consisted of pre-contrast supine KUB, post-contrast supine KUB at the 7th and 15th minutes, and supine pelvic radiographs with full bladder and post-voiding. When needed, additional compression and/or oblique radiographs were taken. In this study, for all patients, a post-contrast 15th minute upright KUB radiograph was added to IVU. Two consecutive radiographs taken at the 15th minute postcontrast in supine and upright positions were evaluated by consensus of 2 radiologists. Primary benefits were improved filling and emptying of the collecting system, and secondary benefits were nephroptosis and ascertaining diagnosis of phlebolith.
RESULTS: Of 170 patients, 337 kidneys and collecting systems (n = 168 right; n = 169 left) were examined. Improved filling, emptying of the collecting system, nephroptosis, ascertaining diagnosis of phleboliths were detected with the rates of 12.5%, 44.2%, 8.3%, and 3.2%, respectively. Improved filling was significant in the presence of hydronephrosis (P < 0.05) and ureterolithiasis (P < 0.05) on both sides. There was a positive correlation between both improved filling and presence of hydronephrosis, and improved filling and presence of ureterolithiasis. Emptying was significant in collecting systems that had no visible pathology on IVU (P < 0.05) on either side.
CONCLUSION: Upright KUB radiographs provide supplementary data about urine flow in terms of improved filling and emptying of the collecting system.

Entities:  

Mesh:

Year:  2008        PMID: 19061166

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  1 in total

1.  The value of X-ray digital tomosynthesis in the diagnosis of urinary calculi.

Authors:  Shifeng Liu; Hong Wang; Weihua Feng; Xiaokun Hu; Jian Guo; Qingjun Shang; Zixiang Li; Hongsheng Yu
Journal:  Exp Ther Med       Date:  2017-11-21       Impact factor: 2.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.