Literature DB >> 19056809

Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist.

Øydis Østbye Lie1, Gudrun Uthaug Paulsen, Tor Wøhni.   

Abstract

This study investigates the relationship between personal dosemeter (PD) reading, effective dose and dose to the lens of the eye for interventional cardiologists in Norway. Doses were recorded with thermoluminescence dosemeters (TLD-100) for 14 cardiologists, and the effective doses were estimated using the Niklason algorithm. The procedures performed were coronary angiography and percutaneous coronary intervention, and all the hospitals (eight) in Norway, which are performing these procedures, were included in the study. Effective dose per unit dose-area product varied by a factor of 5, and effective dose relative to PD reading varied between 4 and 39%. Eye lens doses ranged from 39 to 138% of the dosemeter reading. On the basis of an estimated annual workload of 900 procedures, the annual effective doses ranged from 1 to 11 mSv. The estimated annual doses to the unprotected eye ranged from 9 to 210 mSv. According to the ICRP dose limits, the results indicate that the eye could be the limiting organ.

Entities:  

Mesh:

Year:  2008        PMID: 19056809     DOI: 10.1093/rpd/ncn296

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 2.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

3.  The importance of protection glasses during neuroangiographies: A study on radiation exposure at the lens of the primary operator.

Authors:  J B Tavares; E Sacadura-Leite; T Matoso; L L Neto; L Biscoito; J Campos; A Sousa-Uva
Journal:  Interv Neuroradiol       Date:  2016-02-02       Impact factor: 1.610

Review 4.  Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure.

Authors:  Eugenio Picano; Eliseo Vano; Luciano Domenici; Matteo Bottai; Isabelle Thierry-Chef
Journal:  BMC Cancer       Date:  2012-04-27       Impact factor: 4.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.