Literature DB >> 19051858

Long-term durability of one-step adhesive-composite systems to enamel and dentin.

Richard M Foxton1, Luciana Melo, David G Stone, Peter Pilecki, Martin Sherriff, Timothy F Watson.   

Abstract

This study evaluated the long-term durability of three one-step adhesive-composite systems to ground enamel and dentin. Twenty-seven teeth were randomly divided into three groups of nine. The first group had its crowns sectioned to expose superficial dentin, which was then ground with 600 grit SiC paper. One of three one-step adhesives: a trial bonding agent, OBF-2; i Bond or Adper Prompt L-Pop was applied to the dentin of three teeth and built-up with the corresponding resin composite (Estelite sigma, Venus or Filtek Supreme). The second group of nine teeth had their enamel approximal surfaces ground with wet 600-grit SiC paper, then one of the three one-step adhesives was applied and built-up with resin composite. The bonded specimens were sliced into 0.7 mm-thick slabs. After 24 hours and one year of water storage at 37 degrees C, the slabs were sectioned into beams for the microtensile bond strength test. Failure modes were observed using optical and electron scanning microscopy. The third group of nine teeth had approximal wedge-shaped cavities prepared above the CEJ into dentin. Two-to-three grains of rhodamine B were added to each of the three adhesives prior to restoring the cavities with resin composite. After 24 hours storage, the teeth were sectioned and their interfaces examined with a laser scanning confocal microscope. The bond strengths of the three adhesive-composite systems to both enamel and dentin significantly lessened after one year of water storage, however, there was no significant difference between the materials.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19051858     DOI: 10.2341/07-166

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  6 in total

1.  The competition between enamel and dentin adhesion within a cavity: an in vitro evaluation of class V restorations.

Authors:  Tissiana Bortolotto; Wassila Doudou; Karl Heinz Kunzelmann; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2011-10-21       Impact factor: 3.573

2.  Telechelic poly(2-oxazoline)s with a biocidal and a polymerizable terminal as collagenase inhibiting additive for long-term active antimicrobial dental materials.

Authors:  Christoph P Fik; Stefan Konieczny; David H Pashley; Christian J Waschinski; Reinhild S Ladisch; Ulrich Salz; Thorsten Bock; Joerg C Tiller
Journal:  Macromol Biosci       Date:  2014-08-08       Impact factor: 4.979

3.  Effects of long-term water storage on the microtensile bond strength of five experimental self-etching adhesives based on surfactants rather than HEMA.

Authors:  Cesar Henrique Zanchi; Eliseu Aldrighi Münchow; Fabrício Aulo Ogliari; Rodrigo Varella de Carvalho; Stefano Chersoni; Carlo Prati; Flávio Fernando Demarco; Evandro Piva
Journal:  Clin Oral Investig       Date:  2012-08-12       Impact factor: 3.573

4.  Laboratory evaluation of the effect of unfilled resin after the use of self-etch and total-etch dentin adhesives on the Shear Bond Strength of composite to dentin.

Authors:  Ehsan Baradaran Nasseri; Sara Majidinia; Davood Aghasizadeh Sharbaf
Journal:  Electron Physician       Date:  2017-05-25

5.  Effects of surface treatments of conventional glass-ionomer on shear bond strength to giomer.

Authors:  Soodabeh Kimyai; Narmin Mohammadi; Parnian Alizadeh Oskoee; Mohammad Esmaeel Ebrahimi Chaharom; Mahmood Bahari; Alireza Sadr; Ghazaleh Ahmadizenouz
Journal:  Dent Res J (Isfahan)       Date:  2012-11

Review 6.  Current perspectives on dental adhesion: (2) Concepts for operatively managing carious lesions extending into dentine using bioactive and adhesive direct restorative materials.

Authors:  Richard M Foxton
Journal:  Jpn Dent Sci Rev       Date:  2020-09-20
  6 in total