Is a magic angle effect observed in the collateral ligaments of the distal interphalangeal joint or the oblique sesamoidean ligaments during standing magnetic resonance imaging?

Meredith A Smith1, Sue J Dyson, Rachel C Murray.   

Abstract

Collagen fibers oriented at 55 degrees to the static magnetic field (B0) are characterized by an artifactual increase in signal intensity due to the magic angle effect. We hypothesized that there would be increased signal intensity in the collateral ligaments of the distal interphalangeal joint and oblique sesamoidean ligaments when these ligaments were at angles approaching 55 degrees to a horizontal B0 during standing magnetic resonance (MR) imaging. MR imaging was performed on four cadaver forelimbs in a 0.27 T standing system. Transverse and dorsal images were obtained using various sequences, with limbs angled at 0 degrees, 4 degrees, 8 degrees, and 12 degrees to the vertical. Images were analyzed and the angle of each ligament to B0 determined. Mean signal intensity in the ligament and cortex of the adjacent phalanx was measured and ratios calculated. With subjective interpretation, there was increased signal intensity in the collateral ligaments of the distal interphalangeal joint and oblique sesamoidean ligaments over ranges of angles of 60-78 degrees and 57-69 degrees, respectively, to B0. In fast spin echo (FSE) sequences, with a long echo time (72ms), the effect was less pronounced. FSE sequences can help determine the significance of increased signal intensity within tissues. In spite of limited positions of a limb during standing MR imaging compared with horses under general anesthesia, deviation from a vertical posture sufficient to cause a magic angle effect can still occur in both ligaments tested. Conformation may contribute to the occurrence of the magic angle effect during standing MR imaging. Effort should be made to position horses squarely and to minimize leaning during image acquisition.

Entities:  

Mesh:

Year:  2008        PMID: 19051639     DOI: 10.1111/j.1740-8261.2008.00432.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  1 in total

1.  Use of standing low-field magnetic resonance imaging to assess oblique distal sesamoidean ligament desmitis in three Thoroughbred racehorses.

Authors:  Fumiaki Mizobe; Jun Okada; Yuta Shinzaki; Motoi Nomura; Tomohiro Kato; Kazutaka Yamada; Mathieu Spriet
Journal:  J Vet Med Sci       Date:  2016-06-16       Impact factor: 1.267

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.