Literature DB >> 19047717

A minimally disruptive model and three-dimensional evaluation of Lisfranc joint diastasis.

Vinod K Panchbhavi1, Clark R Andersen, Santaram Vallurupalli, Jinping Yang.   

Abstract

BACKGROUND: There is no model that can reproduce the diastasis at the Lisfranc joint after isolated transection of the Lisfranc ligament. Prior models required extensive sectioning of ligaments in the midfoot and represent injuries that cause extensive tarsometatarsal fracture-dislocations. They do not represent a subset of injuries that cause subtle or limited disruption at the Lisfranc joint. The purpose of this study was to create a model with the minimum amount of ligamentous disruption and loading necessary to consistently observe diastasis at the Lisfranc joint.
METHODS: Fourteen fresh-frozen paired cadaver feet were dissected to expose the dorsum. Three screws were inserted into each first cuneiform and second metatarsal to create a pair of registration triads. A digitizer was utilized to record the three-dimensional positions of the screws and their displacement under loaded and unloaded conditions before and after the Lisfranc ligament was cut (intact and cut conditions). The first and second cuneiforms and their metatarsals were removed, and the attachment sites of the dorsal and the Lisfranc ligament were digitized. The three-dimensional positions of the bones and ligament displacement were determined. The significance of differences between conditions was tested with analysis of variance, and linear regression analysis was used to test the correlation between dorsal and plantar displacements.
RESULTS: There was a significant difference, of 1.3 mm, in the mean displacement between the cut loaded and intact loaded conditions (p < 0.0001). A modest correlation (r(2) = 0.60) was found between dorsal displacement and displacement at the site of the Lisfranc ligament, possibly attributable to rotations between the first cuneiform and second metatarsal.
CONCLUSIONS: Isolated sectioning of the Lisfranc ligament is sufficient to consistently create diastasis at the Lisfranc joint. Dorsal displacements between the first cuneiform and second metatarsal are a modest predictor of plantar displacements.

Entities:  

Mesh:

Year:  2008        PMID: 19047717     DOI: 10.2106/JBJS.G.01420

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  Lisfranc injuries: an update.

Authors:  Kyriacos I Eleftheriou; Peter F Rosenfeld; James D F Calder
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-07       Impact factor: 4.342

2.  The biomechanical study of the influence to the forefoot plantar pressure of the first tarsometatarsal joint fracture-dislocation fixed by three different implants.

Authors:  Xiao Yu; Qing-Jiang Pang; Xian-Jun Chen
Journal:  Pak J Med Sci       Date:  2017 Jan-Feb       Impact factor: 1.088

3.  Anatomical Pathology of Subtle Lisfranc Injury.

Authors:  Naoki Haraguchi; Koki Ota; Takuma Ozeki; Shingo Nishizaka
Journal:  Sci Rep       Date:  2019-10-16       Impact factor: 4.379

4.  Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model.

Authors:  Zachary A Koroneos; Kristen M Manto; Brandon J Martinazzi; Chris Stauch; Shawn M Bifano; Allen R Kunselman; Gregory S Lewis; Michael Aynardi
Journal:  Am J Sports Med       Date:  2022-08-22       Impact factor: 7.010

5.  Finite element analysis of locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation.

Authors:  Xiao Yu; Wei-Long Li; Qing-Jiang Pang; Rong-Li Zhou
Journal:  J Int Med Res       Date:  2017-07-31       Impact factor: 1.671

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.